This is historical information of device classes implemented in AcqPrinceton device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Princeton CCD acquisition device
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| absorptionSpectrum: DevDouble | — |
| acqModeScalar: DevLong | — |
| averageIntensitySpectrum: DevDouble | — |
| checkTemperatureScalar: DevBoolean | — |
| depthScalar: DevLong | — |
| exposureScalar: DevDouble | — |
| fileFormatScalar: DevString | — |
| fileNameScalar: DevString | — |
| fileParmsSpectrum: DevString | — |
| framesScalar: DevLong | — |
| heightScalar: DevLong | — |
| imageImage: DevUShort | — |
| intensitySpectrum: DevDouble | — |
| intensity0Spectrum: DevDouble | — |
| intensityBlackSpectrum: DevDouble | — |
| numFrameScalar: DevLong | — |
| rotateImageScalar: DevLong | — |
| saturationScalar: DevDouble | — |
| saturationAlarmScalar: DevDouble | — |
| saturationMaxScalar: DevDouble | — |
| shutterModeScalar: DevLong | — |
| temperatureScalar: DevDouble | — |
| timingScalar: DevDouble | — |
| triggerScalar: DevLong | — |
| useROIScalar: DevBoolean | — |
| widthScalar: DevLong | — |
| shutterCloseDelayScalar: DevDouble | — |
| roi1xminScalar: DevLong | — |
| roi1xmaxScalar: DevLong | — |
| roi1yminScalar: DevLong | — |
| roi1ymaxScalar: DevLong | — |
| xbinScalar: DevLong | — |
| ybinScalar: DevLong | — |
| nbROIScalar: DevLong | — |
| roiSpectrum: DevLong | — |
| intensityZone1Scalar: DevDouble | — |
| intensityZone2Scalar: DevDouble | — |
| intensityZone3Scalar: DevDouble | — |
| intensityZone4Scalar: DevDouble | — |
| intensityZone5Scalar: DevDouble | — |
| intensityZone6Scalar: DevDouble | — |
| intensityZone7Scalar: DevDouble | — |
| intensityZone8Scalar: DevDouble | — |
| intensityZone9Scalar: DevDouble | — |
| intensityZone10Scalar: DevDouble | — |
| intensityZone11Scalar: DevDouble | — |
| intensityZone12Scalar: DevDouble | — |
| intensityNbZonesScalar: DevLong | — |
| binningSpectrum: DevLong | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| AcquireIntensity0Input: DevVoid Output: DevVoid |
Sets the intensity0 attribute with the latest measured intensity |
| AcquireIntensityBlackInput: DevVoid Output: DevVoid |
Sets the intensityBlack attribute with the latest measured intensity |
| CloseInput: DevVoid Output: DevVoid |
Frees the current camera, prepares it for power-down |
| GetParamInput: DevString Output: DevString |
None. |
| OpenInput: DevVoid Output: DevVoid |
Reserves and initializes the camera hardware - Detects the characteristics of the CCD : width, height, depth wich can be read using the device`s attributes - Sets the desired temperature |
| ResetIntensityBlackInput: DevVoid Output: DevVoid |
None. |
| SetParamInput: DevVarStringArray Output: DevVoid |
None. |
| StartInput: DevVoid Output: DevVoid |
Starts exposing - the desired exposing mode (continuous or sequence) must be previously defined with SetMode() command |
| StopInput: DevVoid Output: DevVoid |
Stops the current sequence of exposing |
Pipes:
Properties:
| Name | Description |
|---|---|
| CamIdDevString | Camera identifier |
| CamTypeDevLong | Camera type 0 = Princeton |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:42 p.m.