This is historical information of device classes implemented in FastRetrigAI device server.
Use this link to find the valid information.
Development status:
Released,
Release: release_1_4_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/InputOutput/FastRetrigAI
Contact:
Class Description
- Fast ADC Tango Interface.
- support NI 5122 and Acqiris DC211 board (for now).
Families: InputOutput
Key words:
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| channel0MaxScalar: DevDouble | — |
| channel0AverageScalar: DevDouble | — |
| channel1MaxScalar: DevDouble | — |
| channel1AverageScalar: DevDouble | — |
| samplingFrequencyScalar: DevDouble | — |
| rangePeakPeakCh0Scalar: DevDouble | — |
| rangePeakPeakCh1Scalar: DevDouble | — |
| verticalOffsetCh0Scalar: DevDouble | — |
| verticalOffsetCh1Scalar: DevDouble | — |
| triggerDelayScalar: DevDouble | — |
| triggerSourceScalar: DevUShort | — |
| errorCounterScalar: DevLong | — |
| timeoutCounterScalar: DevLong | — |
| dataCounterScalar: DevLong | — |
| integrationTimeScalar: DevDouble | — |
| numberOfSamplesByChannelScalar: DevLong | — |
| bandWidthScalar: DevString | — |
| channel0WaveformSpectrum: DevDouble | — |
| channel0TimebaseSpectrum: DevDouble | — |
| channel1WaveformSpectrum: DevDouble | — |
| channel1TimebaseSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
start acquiring |
| StopInput: DevVoid Output: DevVoid |
stop acquiring |
| SelfCalibrateInput: DevVoid Output: DevVoid |
Self calibrates the hardware |
| BandWidthUPInput: DevVoid Output: DevVoid |
increases the input signal bandwidth |
| BandWidthDOWNInput: DevVoid Output: DevVoid |
decreases the input signal bandwidth |
| ResetInput: DevVoid Output: DevVoid |
Resets the following attributes : - channel0Waveform - channel1Waveform |
Pipes:
Properties:
| Name | Description |
|---|---|
| BoardNumDevShort | set value according to the board location |
| BoardTypeDevString | Board type can be: - NI_5122 - ACQUIRIS_DC_211 |
| NumberOfChannelsDevShort | number of activated channels |
| TimeoutDevLong | Timeout callback sent to the user if no data has been received during this Time (ms) |
| AnalogTriggerLevelDevDouble | analog trigger level |
| InternalInputImpedanceDevLong | 50 -> 50 Ohm 1000000 -> 1 MOhm |
| SamplingSourceDevString | INTERNAL or EXTERNAL |
| CouplingDevString | DC or AC |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:35 p.m.