This is historical information of device classes implemented in FastRetrigAI device server.

Use this link to find the valid information.

Development status: Released
Information status: New

Contact:



Class Description


Fast ADC Tango Interface.
support NI 5122 and Acqiris DC211 board (for now).

Families: InputOutput

Key words:

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
channel0MaxScalar: DevDouble
channel0AverageScalar: DevDouble
channel1MaxScalar: DevDouble
channel1AverageScalar: DevDouble
samplingFrequencyScalar: DevDouble
rangePeakPeakCh0Scalar: DevDouble
rangePeakPeakCh1Scalar: DevDouble
verticalOffsetCh0Scalar: DevDouble
verticalOffsetCh1Scalar: DevDouble
triggerDelayScalar: DevDouble
triggerSourceScalar: DevUShort
errorCounterScalar: DevLong
timeoutCounterScalar: DevLong
dataCounterScalar: DevLong
integrationTimeScalar: DevDouble
numberOfSamplesByChannelScalar: DevLong
bandWidthScalar: DevString
channel0WaveformSpectrum: DevDouble
channel0TimebaseSpectrum: DevDouble
channel1WaveformSpectrum: DevDouble
channel1TimebaseSpectrum: DevDouble

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
start acquiring
StopInput: DevVoid
Output: DevVoid
stop acquiring
SelfCalibrateInput: DevVoid
Output: DevVoid
Self calibrates the hardware
BandWidthUPInput: DevVoid
Output: DevVoid
increases the input signal bandwidth
BandWidthDOWNInput: DevVoid
Output: DevVoid
decreases the input signal bandwidth
ResetInput: DevVoid
Output: DevVoid
Resets the following attributes : - channel0Waveform - channel1Waveform

Pipes:

Properties:

Name Description
BoardNumDevShort set value according to the board location
BoardTypeDevString Board type can be: - NI_5122 - ACQUIRIS_DC_211
NumberOfChannelsDevShort number of activated channels
TimeoutDevLong Timeout callback sent to the user if no data has been received during this Time (ms)
AnalogTriggerLevelDevDouble analog trigger level
InternalInputImpedanceDevLong 50 -> 50 Ohm 1000000 -> 1 MOhm
SamplingSourceDevString INTERNAL or EXTERNAL
CouplingDevString DC or AC

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:09 p.m.