This is historical information of device classes implemented in SingleShotAI device server.
Use this link to find the valid information.
Development status:
Released,
Release: release_1_0_0
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/InputOutput/ADLINK/SingleShotAI
Contact:
Class Description
- Performs Analog Input in Single Shot (read ponctually) on board SAI_2005, SAI_2010,
- MAI_2204, MAI_2205.
Families: InputOutput
Key words: ADLINK
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| channel0Scalar: DevDouble | — |
| channel1Scalar: DevDouble | — |
| channel2Scalar: DevDouble | — |
| channel3Scalar: DevDouble | — |
| channel4Scalar: DevDouble | — |
| channel5Scalar: DevDouble | — |
| channel6Scalar: DevDouble | — |
| channel7Scalar: DevDouble | — |
| channel8Scalar: DevDouble | — |
| channel9Scalar: DevDouble | — |
| channel10Scalar: DevDouble | — |
| channel11Scalar: DevDouble | — |
| channel12Scalar: DevDouble | — |
| channel13Scalar: DevDouble | — |
| channel14Scalar: DevDouble | — |
| channel15Scalar: DevDouble | — |
| channel16Scalar: DevDouble | — |
| channel17Scalar: DevDouble | — |
| channel18Scalar: DevDouble | — |
| channel19Scalar: DevDouble | — |
| channel20Scalar: DevDouble | — |
| channel21Scalar: DevDouble | — |
| channel22Scalar: DevDouble | — |
| channel23Scalar: DevDouble | — |
| channel24Scalar: DevDouble | — |
| channel25Scalar: DevDouble | — |
| channel26Scalar: DevDouble | — |
| channel27Scalar: DevDouble | — |
| channel28Scalar: DevDouble | — |
| channel29Scalar: DevDouble | — |
| channel30Scalar: DevDouble | — |
| channel31Scalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ReadChannelInput: DevUShort Output: DevUShort |
Read the current value of the specified channel. |
| ReadScaledChannelInput: DevUShort Output: DevDouble |
Read the current voltage of the specified channel. |
| ReadChannelsInput: DevUShort Output: DevVarUShortArray |
Read all the current values of channel from 0 to argin. |
| ReadScaledChannelsInput: DevUShort Output: DevVarDoubleArray |
Read the current values of all channel from 0 to argin. |
| CalibrateInput: DevVoid Output: DevVoid |
Calibrate the hardware. |
Pipes:
Properties:
| Name | Description |
|---|---|
| BoardNumDevShort | The number of the board in the cPCI chassis (between 0 and 7). |
| BoardTypeDevShort | The board type ( the possible values are SAI_2005, SAI_2010, MAI_2204, MAI_2205). |
| InputRange0DevShort | The input range for channel 0 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange1DevShort | The input range for channel 1 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange2DevShort | The input range for channel 2 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange3DevShort | The input range for channel 3 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange4DevShort | The input range for channel 4 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange5DevShort | The input range for channel 5 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange6DevShort | The input range for channel 6 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange7DevShort | The input range for channel 7 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange8DevShort | The input range for channel 8 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange9DevShort | The input range for channel 9 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange10DevShort | The input range for channel 10 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange11DevShort | The input range for channel 11 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange12DevShort | The input range for channel 12 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange13DevShort | The input range for channel 13 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange14DevShort | The input range for channel 14 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange15DevShort | The input range for channel 15 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange16DevShort | The input range for channel 16 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange17DevShort | The input range for channel 17 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange18DevShort | The input range for channel 18 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange19DevShort | The input range for channel 19 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange20DevShort | The input range for channel 20 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange21DevShort | The input range for channel 21 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange22DevShort | The input range for channel 22 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange23DevShort | The input range for channel 23 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange24DevShort | The input range for channel 25 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange25DevShort | The input range for channel 25 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange26DevShort | The input range for channel 26 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange27DevShort | The input range for channel 27 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange28DevShort | The input range for channel 28 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange29DevShort | The input range for channel 29 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange30DevShort | The input range for channel 30 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
| InputRange31DevShort | The input range for channel 31 ( possible values are B_10, B_5, B_2_5, B_1_25, U_10, U_5, U_2_5, U_1_25 ). |
README
b'//-============================================================\n//\n// This class has been generated by POGO\n// (Program Obviously used to Generate tango Object)\n//\n// (c) - Software Engineering Group - ESRF\n//=============================================================\n\n\nFiles generated:\n===============\nSingleShotAI.cpp: Source code for the SingleShotAI class and its commands.\n This class is derived from DeviceImpl_2 class.\n It represents the CORBA servant obbject which\n will be accessed from the network.\n All commands which can be executed on the\n SingleShotAI are implemented in this file.\n\nSingleShotAI.h: Include for the SingleShotAI class.\n Server class prototypes and descriptions.\n\nSingleShotAIClass.cpp: A singleton class derived fromSingleShotAI.\n It implements the command list and all properties\n and methods required by the SingleShotAI once per process\n\nSingleShotAIClass.h:\tInclude for the SingleShotAIClass root class.\n This class is represents the singleton class for\n the SingleShotAI device class.\n It contains all properties and methods which the \n SingleShotAI requires only once e.g. the commands.\n\nmain.cpp:\t\tC++ source for a TANGO device server main.\n The main rule is to initialise (and create) the Tango\n system and to create the DServerClass singleton.\n The main should be the same for every Tango device server.\n\nClassFactory.cpp:\tC++ source for the class_factory method of the DServer\n device class. This method is responsible to create\n all class singletin for a device server. It is called\n at device server startup\n'
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.