This is historical information of device classes implemented in TripleGenericMirror device server.
Use this link to find the valid information.
Development status:
Released,
Release: SOLEIL_ROOT_RELEASE_5_5_6
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/Mirrors/TripleGenericMirror
Contact:
Class Description
This device is used to pilot a triple mirror
Families: BeamlineComponents
Key words: Mirrors
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| beamRotationScalar: DevDouble | — |
| beamTranslationScalar: DevDouble | — |
| currentWayScalar: DevString | — |
| mirrorARotationScalar: DevDouble | — |
| mirrorBRollScalar: DevDouble | — |
| mirrorBYawScalar: DevDouble | — |
| mirrorCRollScalar: DevDouble | — |
| mirrorCYawScalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StopInput: DevVoid Output: DevVoid |
Stop all the motors |
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| InitializeMirrorInput: DevVoid Output: DevVoid |
Method to initialize all the object needed by the device mirror |
| ChooseWayInput: DevUShort Output: DevVoid |
Method to change the wanted way (A or B) of the mirror and the beam |
Pipes:
Properties:
| Name | Description |
|---|---|
| MirrorCYawWayADevDouble | — |
| MirrorBYawWayADevDouble | — |
| MirrorBYawWayBDevDouble | — |
| AttributePositionNameDevString | Give the name of the attribute to move the motor according the motors device used. |
| CommandStateNameDevString | Gives the name of the STATE command according the target device. For SimulatedMotor it is State. |
| CommandStopNameDevString | Name of the command stop for the reached device. |
| BeamRotationMotorNameDevString | — |
| BeamTranslationMotorNameDevString | — |
| MirrorARotationMotorNameDevString | — |
| MirrorBYawMotorNameDevString | — |
| MirrorCYawMotorNameDevString | — |
| MirrorBRollMotorNameDevString | — |
| MirrorCRollMotorNameDevString | — |
| Has7MotorsDevBoolean | — |
| BeamRotationWayADevDouble | — |
| BeamRotationWayBDevDouble | — |
| BeamTranslationWayADevDouble | — |
| BeamTranslationWayBDevDouble | — |
| MirrorARotationWayADevDouble | — |
| MirrorARotationWayBDevDouble | — |
| MirrorCYawWayBDevDouble | — |
| MirrorBRollWayADevDouble | — |
| MirrorBRollWayBDevDouble | — |
| MirrorCRollWayADevDouble | — |
| MirrorCRollWayBDevDouble | — |
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.