TripleGenericMirror - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: New development
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/Mirrors/TripleGenericMirror
Contact:



Class Description


This device is used to pilot a triple mirror

Families: BeamlineComponents

Key words: Mirrors

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
beamRotationScalar: DevDouble —
beamTranslationScalar: DevDouble —
currentWayScalar: DevString —
mirrorARotationScalar: DevDouble —
mirrorBRollScalar: DevDouble —
mirrorBYawScalar: DevDouble —
mirrorCRollScalar: DevDouble —
mirrorCYawScalar: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StopInput: DevVoid
Output: DevVoid
Stop all the motors
InitializeMirrorInput: DevVoid
Output: DevVoid
Method to initialize all the object needed by the device mirror
ChooseWayInput: DevUShort
Output: DevVoid
Method to change the wanted way (A or B) of the mirror and the beam

Pipes:

Properties:

Name Description
MirrorARotationWayBDevDouble —
MirrorBYawWayADevDouble —
MirrorBYawWayBDevDouble —
AttributePositionNameDevString Give the name of the attribute to move the motor according the motors device used.
CommandStateNameDevString Gives the name of the STATE command according the target device. For SimulatedMotor it is State.
CommandStopNameDevString Name of the command stop for the reached device.
BeamRotationMotorNameDevString —
BeamTranslationMotorNameDevString —
MirrorARotationMotorNameDevString —
MirrorBYawMotorNameDevString —
MirrorCYawMotorNameDevString —
MirrorBRollMotorNameDevString —
MirrorCRollMotorNameDevString —
Has7MotorsDevBoolean —
BeamRotationWayADevDouble —
BeamRotationWayBDevDouble —
BeamTranslationWayADevDouble —
BeamTranslationWayBDevDouble —
MirrorARotationWayADevDouble —
MirrorCYawWayADevDouble —
MirrorCYawWayBDevDouble —
MirrorBRollWayADevDouble —
MirrorBRollWayBDevDouble —
MirrorCRollWayADevDouble —
MirrorCRollWayBDevDouble —


Please log in to comment.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:34 a.m.