MythenWAXS - - TANGO Controls

This is historical information of device classes implemented in MythenWAXS device server.

Use this link to find the valid information.

Development status: Released, Release: FIRST_TEST_ON_BEAMLINE
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/1D/MythenWAXS
Contact:



Class Description


Manage a pool of Mythen2 detectors

Families: Acquisition

Key words:

Platform: All Platforms

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: SOLEIL

Bus: Not Applicable

Class interface


Attributes:

Name Description
energyScalar: DevFloat —
thresholdScalar: DevFloat —
exposureTimeScalar: DevDouble —
nbFramesScalar: DevLong —
flatFieldCorrectionScalar: DevBoolean —
rateCorrectionScalar: DevBoolean —
badChannelInterpolationScalar: DevBoolean —
nbModulesScalar: DevLong —
nbChannelsScalar: DevLong —
frameXSpectrum: DevFloat —
frameYSpectrum: DevFloat —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
SnapInput: DevVoid
Output: DevVoid
Arm/Start the acquisition.
StopInput: DevVoid
Output: DevVoid
—

Pipes:

Properties:

Name Description
ProxyMythenNamesArray of DevString A list of a proxies name to Myhten2Detector devices
ProxyNbRetryDevULong —
ProxyMotorNameDevString —
EquationParametersArray of DevString —
PixelSizeDevFloat Mythen2 Detector pixel size (in mm)
AutoWriteHardwareAtInitDevBoolean Enable/Disable write hardware at init (energy/threshold/...)
MemorizedEnergyDevFloat Memorized Energy
MemorizedThresholdDevFloat Memorized Threshold
MemorizedExposureTimeDevDouble Memorized ExposureTime
MemorizedNbFramesDevLong Memorized NbFrames
MemorizedFlatFieldCorrectionDevBoolean Memorized FlatFieldCorrection
MemorizedRateCorrectionDevBoolean Memorized RateCorrection
MemorizedBadChannelInterpolationDevBoolean Memorized BadChannelInterpolation

19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



24 Mar 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



10 Feb 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:22 Feb 2018, 1:56 p.m.