ScientaMultiregion - - TANGO Controls

This is historical information of device classes implemented in ScientaMultiregion device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated

Contact:



Class Description


Tango device that monitors a ScientaAcquisition device to perform acquisiotions on several regions of one spectrum

Families: Acquisition

Key words: - 2D

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
numRegionsScalar: DevUShort —
regionInProgressScalar: DevULong —
excitationEnergyScalar: DevDouble —
passModeScalar: DevString —
detectorFirstXChannelScalar: DevShort —
detectorLastXChannelScalar: DevShort —
detectorFirstYChannelScalar: DevShort —
detectorLastYChannelScalar: DevShort —
detectorSlicesScalar: DevShort —
ADCModeScalar: DevShort —
ADCMaskScalar: DevShort —
discriminatorLevelScalar: DevShort —
scanServerAdapterScalar: DevDouble —
highEnergySpectrum: DevDouble —
lowEnergySpectrum: DevDouble —
fixEnergySpectrum: DevDouble —
energyStepSpectrum: DevDouble —
stepTimeSpectrum: DevDouble —
lensModeSpectrum: DevString —
passEnergySpectrum: DevDouble —
modeSpectrum: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ValidateConfigurationInput: DevVoid
Output: DevVoid
None.
ResetConfigurationInput: DevVoid
Output: DevVoid
None.
StartInput: DevVoid
Output: DevVoid
Launch a multi region acquisition
StopInput: DevVoid
Output: DevVoid
Stops the current acquisition

Pipes:

Properties:

Name Description
TargetDeviceDevString ScientaAcquistion device to be monitored
MaxNumberOfRegionsDevLong Max number of regions for acquisition

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:16 Feb 2018, 11:43 a.m.