This is historical information of device classes implemented in CYBERSTAR device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Contact:
Class Description
- This device controls the pulse processing unit (PPU) of a fast scintillation detector (SD).
- This PPU is called CYBERSTAR. This product come from OXFORD DANFYSIK. The device controls the 3 parts of the PPU thanks to a RS232 link. 1- the high voltage module. (Voltage applied to the photomultplier of SD) 2- the preamplifier and shaping Amplifier module.(pulses shaping) 3- the Single Channel Annalyser.(energy selector).
Families: Acquisition
Key words: 2D
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| voltageScalar: DevDouble | — |
| forcedRemoteModeScalar: DevBoolean | — |
| amplifierGainScalar: DevDouble | — |
| peakingTimeScalar: DevDouble | — |
| scaLowerThresholdScalar: DevDouble | — |
| scaUpperThresholdScalar: DevDouble | — |
| windowWidthScalar: DevDouble | — |
| windowCenterPositionScalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
| Name | Description |
|---|---|
| SerialProxyNameDevString | name of the Serial Line device Proxy |
| MaxThresholdDevFloat | Maximum voltage for upper threshold attribute |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:16 Feb 2018, 11:33 a.m.