BakeOutControlDS - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: New development
Information status: New
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Vacuum/BakeOutControlDS
Contact:



Class Description


Families: Vacuum

Key words:

Platform: All Platforms

Language: Python

License:

Contact:

Class interface


Attributes:

Name Description
Temperature_AllSpectrum: DevDouble —
Program_7_ZonesSpectrum: DevShort —
Temperature_8Scalar: DevDouble —
Program_6_ParamsSpectrum: DevDouble —
Program_5_ZonesSpectrum: DevShort —
Temperature_2Scalar: DevDouble —
Temperature_3Scalar: DevDouble —
Temperature_1Scalar: DevDouble —
Temperature_6Scalar: DevDouble —
Output_5_LimitScalar: DevShort —
Temperature_4Scalar: DevDouble —
Temperature_5Scalar: DevDouble —
Program_2_ZonesSpectrum: DevShort —
Output_6_LimitScalar: DevShort —
PressureScalar: DevDouble —
Output_8Scalar: DevShort —
Output_4_LimitScalar: DevShort —
Program_4_ParamsSpectrum: DevDouble —
Program_1_ZonesSpectrum: DevShort —
Program_8_ZonesSpectrum: DevShort —
Output_3_LimitScalar: DevShort —
Output_2_LimitScalar: DevShort —
Program_2_ParamsSpectrum: DevDouble —
Temperature_SetPointScalar: DevDouble —
Temperature_MaxScalar: DevDouble —
Program_3_ParamsSpectrum: DevDouble —
Pressure_SetPointScalar: DevDouble —
Program_3_ZonesSpectrum: DevShort —
Program_8_ParamsSpectrum: DevDouble —
Output_6Scalar: DevShort —
Output_7Scalar: DevShort —
Output_4Scalar: DevShort —
Output_5Scalar: DevShort —
Output_2Scalar: DevShort —
Output_3Scalar: DevShort —
Output_1Scalar: DevShort —
Output_1_LimitScalar: DevShort —
Program_1Image: DevDouble —
Program_2Image: DevDouble —
Program_3Image: DevDouble —
Program_4Image: DevDouble —
Program_5Image: DevDouble —
Program_6Image: DevDouble —
Program_7Image: DevDouble —
Program_8Image: DevDouble —
Temperature_7Scalar: DevDouble —
Output_7_LimitScalar: DevShort —
Program_1_ParamsSpectrum: DevDouble —
Output_8_LimitScalar: DevShort —
Program_4_ZonesSpectrum: DevShort —
Program_6_ZonesSpectrum: DevShort —
Program_5_ParamsSpectrum: DevDouble —
Program_7_ParamsSpectrum: DevDouble —

Commands:

Name Description
ResetInput: DevVoid
Output: DevVoid
—
StopInput: DevShort
Output: DevVoid
—
StartInput: DevShort
Output: DevVoid
—
CheckStatusInput: DevVoid
Output: DevString
—
CheckPressureInput: DevVoid
Output: DevDouble
—
SendCommandInput: DevVarStringArray
Output: DevString
—

Pipes:

Properties:

Name Description
PressureAttributeDevString —
TemperatureSetPointDevDouble —
CommsDeviceDevString —
ControllerTypeDevString
PressureSetPointDevDouble —


Please log in to comment.

16 Jan 2018, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:16 Jan 2018, 1:24 p.m.