This is historical information of device classes implemented in AcromagXT1121 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Setting the Acromag XT1121 digital IO
Families: InputOutput
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Acromag
Product:
XT1121-00
Bus: Modbus
Class interface
Attributes:
| Name | Description |
|---|---|
| Register0Scalar: DevLong | Mask (in decimal) of the register (1 -> output is ON). Each register represent 4 channel (4 bits) |
| Register1Scalar: DevLong | Mask (in decimal) of the register (1 -> output is ON). Each register represent 4 channel (4 bits) |
| Register2Scalar: DevLong | Mask (in decimal) of the register (1 -> output is ON). Each register represent 4 channel (4 bits) |
| Register3Scalar: DevLong | Mask (in decimal) of the register (1 -> output is ON). Each register represent 4 channel (4 bits) |
| PositionScalar: DevDouble | Mask (in decimal) of the 4 registers (1 -> output is ON). Each register has 4 channels (4x4 bits) |
| BitsDelayScalar: DevDouble | Time delay between changes in the bits state. |
| UnitLimitMaxScalar: DevDouble | — |
| UnitLimitMinScalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
| Name | Description |
|---|---|
| ModbusIPAddressDevString | IP address of the Modbus device |
| PortNbDevLong | Port number |
Updated:
The device class has been updated.
You can see previous version here .
3 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
13 Jan 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
25 Nov 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
18 Nov 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
29 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Created:
The device class has been added to catalogue.