Contact:



Class Description


Device server for the Micro-Epsilon optoNCDT ILR 1181-30 and 1182-30. Does not support alarm function and trigger mode.

Families: MeasureInstruments

Key words:

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Micro-Epsilon

Product:

ILR118x

Bus: Serial Line

Class interface


Attributes:

Name Description
DistanceScalar: DevFloat Measured distance to target.
ModeScalar: DevUChar Operation mode: 0 = Normal distance tracking (standard) 1 = Distance tracking up to 7 m (see manual!) 2 = Distance tracking with cooperative target at 10Hz (best accuracy) 3 = Distance tracking with cooperative target at 50Hz
IntervalScalar: DevUChar Number of moving average samples 1 means feature is turned off Maximum is 20.
FrequencyScalar: DevFloat Sets the rate of measured values per second. If the target reflects poorly you`d have to decrease this. If set to 0, the detector will automatically determine the fastest rate possible.
SlopeScalar: DevFloat Scales the measured values according to this factor. May be used for parallax error correction.
OffsetScalar: DevFloat —
TemperatureScalar: DevShort Internal detector temperature.
DeviceScalar: DevString —
SerialNumberScalar: DevString —
FirmwareVersionScalar: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Start data acquisition.
StopInput: DevVoid
Output: DevVoid
Stop data aquisition.

Pipes:

Properties:

Name Description
ConnectionDevString If the connection is made local (local) or remote (remote) via a terminal server.
HostDevString Hostname or IP of the terminal server for remote connection.
PortDevString Port used on the terminal server for remote connection.
DeviceDevString Device node used for local connection.
BaudRateDevULong Connection speed in bits/s. Used for local connections only.
DataBitsDevUShort Number of data bits. Used for local connections only.
ParityDevString Wheter and what kind of parity bit is used. May be none (N), odd (O), even (E), mark (M), or space (S). Used for local connections only.
StopBitsDevUShort How many stop bits are used - for local connections only.
FlowControlDevString Whether XON/XOFF (software), CTS/RTS (hardware) or no (none) flow control is used.
TimeOutDevUShort Connection timeout in deciseconds. It has to be between 1 and 255ds.
AutoReconnectDevString Whether the server will automatically try to reconnect on errors.