This is historical information of device classes implemented in KromoTX1easyXAFS device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
Class for controlling the Kromo-TX1 color tender X-ray camera from easyXAFS
Families: Acquisition
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: easyXAFS
Product:
Kromo-TX1 Color Tender X-ray camera
Bus: USB
Class interface
Attributes:
| Name | Description |
|---|---|
| ExpositionTimeScalar: DevDouble | — |
| GainScalar: DevLong | — |
| FramesPerSecondScalar: DevDouble | If HighSpeedMode == 0 -> max value is 80 If HighSpeedMode == 1 -> max values is 170 |
| HighSpeedModeScalar: DevLong | 0-> off, 1-> on |
| FileDirScalar: DevString | Save directory |
| FilePrefixScalar: DevString | Prefix of the file were the data and parameters are save. Data is saved in [FilePrefix][FileIndex]_array.npy. Parameters in [FilePrefix]_parameters. If the file [FilePrefix][FileIndex]_parameters exists, the data are loaded and not new data are taken. |
| TemperatureScalar: DevDouble | — |
| RoIMinScalar: DevLong | — |
| RoIMaxScalar: DevLong | — |
| FileIndexScalar: DevLong | Index to append to the file name. It will be increased by one after use. Avoid loading of files if not explicitly wanted. |
| RoICountsScalar: DevDouble | Counts in RoI |
| DataSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartAcquisitionInput: DevVoid Output: DevVoid |
Start acquisition |
| StopAcquisitionInput: DevVoid Output: DevVoid |
— |
Pipes:
Properties:
| Name | Description |
|---|---|
| kromo_pidsArray of DevLong | Process ids from last server running. Filled by the tango device. |
README
b'It can not be started with Astor if the remaining threads are not killed\nper hand. The starting script and the Tango Server kill them at init.'
Updated:
The device class has been updated.
You are looking at this version now.
2 Sep 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
26 Aug 2017, Piotr Goryl
Created:
The device class has been added to catalogue.