Class for controlling the Kromo-TX1 color tender X-ray camera from easyXAFS

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: easyXAFS

Product:

Kromo-TX1 Color Tender X-ray camera

Bus: USB

Class interface


Attributes:

Name Description
ExpositionTimeScalar: DevDouble —
GainScalar: DevLong —
FramesPerSecondScalar: DevDouble If HighSpeedMode == 0 -> max value is 80 If HighSpeedMode == 1 -> max values is 170
HighSpeedModeScalar: DevLong 0-> off, 1-> on
FileDirScalar: DevString Save directory
FilePrefixScalar: DevString Prefix of the file were the data and parameters are save. Data is saved in [FilePrefix][FileIndex]_array.npy. Parameters in [FilePrefix]_parameters. If the file [FilePrefix][FileIndex]_parameters exists, the data are loaded and not new data are taken.
TemperatureScalar: DevDouble —
RoIMinScalar: DevLong —
RoIMaxScalar: DevLong —
FileIndexScalar: DevLong Index to append to the file name. It will be increased by one after use. Avoid loading of files if not explicitly wanted.
RoICountsScalar: DevDouble Counts in RoI
DataSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcquisitionInput: DevVoid
Output: DevVoid
Start acquisition
StopAcquisitionInput: DevVoid
Output: DevVoid
—

Pipes:

Properties:

Name Description
kromo_pidsArray of DevLong Process ids from last server running. Filled by the tango device.

README

b'It can not be started with Astor if the remaining threads are not killed\nper hand. The starting script and the Tango Server kill them at init.'

9 Sep 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



2 Sep 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



26 Aug 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:2 Sep 2017, 3:01 a.m.