NXSRecSelector - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released, Release: v3.9.1
Information status: New
Repository: https://github.com/nexdatas/recselector
Contact:



Class Description


Tango server with Sardana Recorder settings

Source code: https://github.com/nexdatas/recselector Web page: https://nexdatas.github.io/recselector NexDaTaS Web page: https://nexdatas.github.io

Families: Acquisition

Key words:

Platform: All Platforms

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: DESY

Bus: Not Applicable

Class interface


Attributes:

Name Description
StepDataSourcesScalar: DevString list of datasources to be switched into step mode
VersionScalar: DevString server version
MacroServerScalar: DevString Macro Server device name
MntGrpScalar: DevString Measurement Group name
ScanDirScalar: DevString Scan Directory
ScanIDScalar: DevLong Scan ID
ScanFileScalar: DevString Scan File(s)
ConfigDeviceScalar: DevString Configuration Device name
DoorScalar: DevString Door device name
WriterDeviceScalar: DevString Writer device device name
UserDataScalar: DevString JSON dictionary with User Data
DeviceGroupsScalar: DevString JSON dictionary with device groups
ProfileConfigurationScalar: DevString JSON dict of server configuration
AppendEntryScalar: DevDouble flag for entry appending
ConfigVariablesScalar: DevString JSON dictionary with configuration variables for templated components
ProfileFileScalar: DevString config file with its full path
LinkDataSourcesScalar: DevString list of datasources to which a link will be added
ComponentsSpectrum: DevString list of Selected Components
DescriptionErrorsSpectrum: DevString list of Descriptive Component Errors
DataSourcesSpectrum: DevString list of Selected Datasources

Commands:

Name Description
AvailableComponentsInput: DevVoid
Output: DevVarStringArray
list of available component names
Return a list of available component names
AvailableDataSourcesInput: DevVoid
Output: DevVarStringArray
list of available DataSource names
Return a list of available DataSource names
AvailableMntGrpsInput: DevVoid
Output: DevVarStringArray
list of available mntgrp names
Return a list of available mntgrp names
AvailableProfilesInput: DevVoid
Output: DevVarStringArray
list of available selection names
Return a list of available selection names
AvailableTimersInput: DevVoid
Output: DevVarStringArray
list of available timers
Return a list of available component names
ChannelPropertiesInput: DevString
property type
Output: DevString
JSON dictionary with channel properties {channel:property}
Provide JSON dictionary with channel properties {channel:property}
ComponentClientSourcesInput: DevVarStringArray
list of required components
Output: DevString
JSON with description of CLIENT Datasources
Describe client datasources from components
ComponentDataSourcesInput: DevVoid
Output: DevVarStringArray
profile component datasources
Provide the component datasources
ComponentDescriptionInput: DevVoid
Output: DevString
JSON component description
Return a list of available component names
CreateDynamicComponentInput: DevVarStringArray
list of JSON strings with datasource parameters
Output: DevString
name of dynamic Component
Create dynamic component
CreateWriterConfigurationInput: DevVarStringArray
list of required components
Output: DevVoid
Create configuration from the given components
DataSourceDescriptionInput: DevVarStringArray
list of required datasources
Output: DevVarStringArray
list of JSON with description of CLIENT Datasources
Provide datasource description
DeleteAllProfilesInput: DevVoid
Output: DevVoid
Delete all profiles from Configuration Server
DeleteProfileInput: DevString
mntgrp name
Output: DevVoid
Delete the given mntgrp
ExportEnvProfileInput: DevVoid
Output: DevVoid
Export all environment variables
FetchProfileInput: DevVoid
Output: DevVoid
Fetch server configuration
FullDeviceNamesInput: DevVoid
Output: DevString
JSON Dictionary with full device names for all aliases
Return a JSON with full device names for all aliases
ImportEnvProfileInput: DevVoid
Output: DevVoid
Import all environment variables
ImportMntGrpInput: DevVoid
Output: DevVoid
Import active mntgrp configuration
IsMntGrpUpdatedInput: DevVoid
Output: DevBoolean
true if mntgrp changed
True if mntgrp was changed
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
AdministratorDataNamesInput: DevVoid
Output: DevVarStringArray
administrator data names
Provide Administrator Data Names
LoadProfileInput: DevVoid
Output: DevVoid
Load server configuration
MandatoryComponentsInput: DevVoid
Output: DevVarStringArray
component names
Set the mandatory components
MntGrpConfigurationInput: DevVoid
Output: DevString
mntgrp configuration string
Provide mntgrp configuration in json string
MutedChannelsInput: DevVoid
Output: DevVarStringArray
list of muted channels
Return a list of muted channel names
PoolElementNamesInput: DevString
pool list attribute name
Output: DevVarStringArray
list of available pool elements
Return a list of available pool channels
PreselectComponentsInput: DevVoid
Output: DevVoid
Check existing devices of pools
PreselectedComponentsInput: DevVoid
Output: DevVarStringArray
component names
Provide the preselected components
PreselectedDataSourcesInput: DevVoid
Output: DevVarStringArray
datasources names
Provide the preselected components
RemoveDynamicComponentInput: DevString
name of dynamic Component
Output: DevVoid
Delete the given dynamic component
ResetPreselectedComponentsInput: DevVoid
Output: DevVoid
Reset PreselectedComponents to DefaultPreselectedComponents
SaveProfileInput: DevVoid
Output: DevVoid
Save server configuration
ScanEnvVariablesInput: DevVoid
Output: DevString
environment data
Fetch ScanDir, ScanFile, ScanID and NeXusSelectorDevice in environment variables
SelectedComponentsInput: DevVoid
Output: DevVarStringArray
component names
Provide the selected components
SelectedDataSourcesInput: DevVoid
Output: DevVarStringArray
profile datasources
Provide the selected datasources
SetChannelPropertiesInput: DevVarStringArray
a two element list with a property type and JSON value dictionary {channel:property}
Output: DevVoid
Set Channel Properties of the given type
SetScanEnvVariablesInput: DevString
environment data
Output: DevLong
scanID
Store ScanDir, ScanFile and NeXusSelectorDevice in environment variables
StoreProfileInput: DevVoid
Output: DevVoid
Store server configuration
SwitchProfileInput: DevVoid
Output: DevVoid
Switch mntgrp configuration
UpdateConfigVariablesInput: DevVoid
Output: DevVoid
Send ConfigVariables into ConfigServer and update serialno if appendEntry selected
UpdateMntGrpInput: DevVoid
Output: DevString
configuration
Update mntgrp configuration
UpdateProfileInput: DevVoid
Output: DevString
mntgrp configuration string
Update mntgrp configuration
VariableComponentsInput: DevVoid
Output: DevString
JSON Dictionary with all Components for configuration variable
Return a list of available component names
ComponentSourcesInput: DevVarStringArray
list of required components
Output: DevString
JSON with description of Datasources
Describe datasources from components

Pipes:

Properties:

Name Description
NumberOfThreadsDevLong maximal number of threads
PoolBlacklistArray of DevString blacklist of pools
TimerFiltersArray of DevString list of timer filters
MutedChannelFiltersArray of DevString list of muted channel filters
AdminDataNamesArray of DevString list of administrator data names
DefaultPreselectedComponentsArray of DevString list of default preselected components
DefaultNeXusPathDevString default NeXus path
DefaultTimeZoneDevString default time zone
DefaultMntGrpDevString defaultmeasurement group name


Please log in to comment.

README

b"========================================\nWelcome to nxsrecconfig's documentation!\n========================================\n\nAuthors: Jan Kotanski\nIntroduction\n\nTango server with Sardana Recorder settings\n\nTango Server API: https://nexdatas.github.io/recselector/doc_html\n\n| Source code: https://github.com/nexdatas/recselector\n| Web page: https://nexdatas.github.io/recselector\n| NexDaTaS Web page: https://nexdatas.github.io\n\n------------\nInstallation\n------------\n\nInstall the dependencies:\n\n| Sardana, PyTango, sphinx\n\nFrom sources\n^^^^^^^^^^^^\n\nDownload the latest version of NeXuS Configuration Server from\n\n| https://github.com/nexdatas/recselector\n\nExtract the sources and run\n\n.. code-block:: console\n\n\t $ python setup.py install\n\nDebian packages\n^^^^^^^^^^^^^^^\n\nDebian Jessie (and Wheezy) packages can be found in the HDRI repository.\n\nTo install the debian packages, add the PGP repository key\n\n.. code-block:: console\n\n\t $ sudo su\n\t $ wget -q -O - http://repos.pni-hdri.de/debian_repo.pub.gpg | apt-key add -\n\nand then download the corresponding source list\n\n.. code-block:: console\n\n\t $ cd /etc/apt/sources.list.d\n\t $ wget http://repos.pni-hdri.de/jessie-pni-hdri.list\n\nFinally,\n\n.. code-block:: console\n\n\t $ apt-get update\n\t $ apt-get install python-nxsrecselector\n\nTo instal other NexDaTaS packages\n\n.. code-block:: console\n\n\t $ apt-get install python-nxswriter nxsconfigtool nxstools python-nxsconfigserver nxsconfigserver-db\n\nand\n\n.. code-block:: console\n\n\t $ apt-get install nxselector python-sardana-nxsrecorder\n\nfor Component Selector and Sardana related packages.\n\n-------------------\nSetting environment\n-------------------\n\n\nSetting Saradna\n^^^^^^^^^^^^^^^\nIf sardana is not yet set up run\n\n\n.. code-block:: console\n\n\t $ Pool\n\n- enter a new instance name\n- create the new instance\n\nThen wait a while until Pool is started and in a new terminal run\n\n.. code-block:: console\n\n\t $ MacroServer\n\n- enter a new instance name\n- create the new instance\n- connect pool\n\nNext, run Astor and change start-up levels: for Pool to 2,\nfor MacroServer to 3 and restart servers.\n\nAlternatively, terminate Pool and MacroServer in the terminals and run\n\n.. code-block:: console\n\n $ nxsetup -s Pool -l2\n\nwait until Pool is started and run\n\n.. code-block:: console\n\n $ nxsetup -s MacroServer -l3\n\n\nAdditionally, one can create dummy devices by running sar_demo in\n\n.. code-block:: console\n\n\t $ spock\n\n\n\nSetting NeXus Servers\n^^^^^^^^^^^^^^^^^^^^^\n\nTo set up NeXus Servers run\n\n.. code-block:: console\n\n\t $ nxsetup -x\n\nor\n\n.. code-block:: console\n\n $ nxsetup -x NXSDataWriter\n $ nxsetup -x NXSConfigServer\n\t $ nxsetup -x NXSRecSelector\n\nfor specific servers.\n\nIf the RecoderPath property of MacroServer is not set one can do it by\n\n.. code-block:: console\n\n\t $ nxsetup -a /usr/lib/python2.7/dist-packages/sardananxsrecorder\n\nwhere the path should point the sardananxsrecorder package.\n"

8 Jun 2017, Jan Kotanski
Created:
The device class has been added to catalogue.