Class Description


This device controls a Tim IQ card whose function is to de-phase a sinusoidal voltage
signal from 2 voltage commands: - IValue - QValue

Families: CounterTimer

Key words: Miscellaneous

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
workingFrequencyScalar: DevDouble —
boardTemperatureScalar: DevDouble —
iValueScalar: DevDouble —
qValueScalar: DevDouble —
mixerCosOutputScalar: DevDouble —
mixerSinOutputScalar: DevDouble —
mixerMaxCosOutputScalar: DevDouble —
mixerMaxSinOutputScalar: DevDouble —
mixerCosPhaseScalar: DevDouble —
mixerSinPhaseScalar: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
AcknowledgeErrorsInput: DevVoid
Output: DevVoid
Acknowledgment of all errors.
PLLcalibrationInput: DevVoid
Output: DevVoid
PLL calibration of TimIQ card.
ResetInput: DevVoid
Output: DevVoid
Resets the TimIQ card.

Pipes:

Properties:

Name Description
IPaddressDevString Embeded Web server IP address. Mandatory
PortDevShort Embeded Web server port number. Mandatory
TminDevDouble Minimum temperature, in degree Celsius, for triggering an ALARM state.
TmaxDevDouble Maximum temperature, in degree Celsius, for triggering an ALARMstate
WorkingFrequencyDevDouble The TimIQ card input frequency, in Hz.
MixerMaxCosOutputDevDouble The 0 degree mixer max cosinus output, in volts.
MixerMaxSinOutputDevDouble The 90 degree mixer max sinus output, in volts.
MixerCosPhaseDevDouble The 0 degree mixer cosinus phase, in degree.
MixerSinPhaseDevDouble The 90 degree mixer sinus phase, in degree.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:09 p.m.