Contact:



Class Description


This Tango class is the interface of the Instrumentation Technologies (IT) Libera
Brillance Single Pass equipment. This class supports only a subset of all the equipment features. It is the basic equipment for a Injection and Transfer Efficiency Measurement System

Families: BeamDiagnostics

Key words: BeamDiag

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Instrumentation Technologies

Product:

Libera Brillance Single Pass

Bus: Not Applicable

Class interface


Attributes:

Name Description
BufferSizeScalar: DevLong —
LevelScalar: DevLong —
TriggerCounterScalar: DevULong —
Fan1SpeedScalar: DevUShort —
Fan2SpeedScalar: DevUShort —
Temp1Scalar: DevUShort —
Temp2Scalar: DevUShort —
Temp3Scalar: DevUShort —
UpSpectrum: DevShort —
DownSpectrum: DevShort —
LeftSpectrum: DevShort —
RightSpectrum: DevShort —
UpTSpectrum: DevDouble —
DownTSpectrum: DevDouble —
LeftTSpectrum: DevDouble —
RightTSpectrum: DevDouble —
ZpositionSpectrum: DevDouble —
XpositionSpectrum: DevDouble —
CurrentSpectrum: DevDouble —
SumTSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
Reset the device in case of fault
ResetTriggerInput: DevVoid
Output: DevVoid
Reset the trigger counter

Pipes:

Properties:

Name Description
ServiceTaskSleepDevLong Sleeping time (in mS) for the service task between libera boxes request
DataTaskHeartbeatDevLong Heartbeat time (in mS) for the data task
LiberaIpAddrDevString Libera IP address
LiberaMulticastIpAddrDevString The IP address used by the Libera box for multicast communication
LiberaPortDevShort The port number on which the generic server running on the LIbera box is listening
LocationDevString The libera box physical place (TL1, BOOSTER,....)
ServiceTaskSleepDevLong Sleeping time (in mS) for the class task between libera boxes request
DataTaskHeartbeatDevLong Heartbeat time (in mS) for the data task
BeamThresholdDevDouble Threshold to decide if there is some beam at a given time (at a given index in the ADC buffers)
PositionKDevDouble Multiplicatif coefficient to compute beam position
CurrentKDevDouble Multiplicative coefficient to compute beam current
CurrentTimeOffsetDevLong Time coefficient used in current computation

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:20 Apr 2017, 1:05 p.m.