This is historical information of device classes implemented in Xbpm device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
- This class is an universal Xbpm controller.
- Xpbm Currents (mA) and Beam Position X (�m) and Z (�m) will be processed by this class.
Families: BeamDiagnostics
Key words: BeamDiag
Platform: All Platforms
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| gainScalar: DevDouble | — |
| enableAutoRangeScalar: DevBoolean | — |
| current1Scalar: DevDouble | — |
| current2Scalar: DevDouble | — |
| current3Scalar: DevDouble | — |
| current4Scalar: DevDouble | — |
| intensityScalar: DevDouble | — |
| measurementUnitScalar: DevString | — |
| horizontalPositionScalar: DevDouble | — |
| verticalPositionScalar: DevDouble | — |
| computationModeScalar: DevUShort | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
Starts acquisition in continuous mode. |
| StopInput: DevVoid Output: DevVoid |
Stops acquisition |
| SetUnitInput: DevUShort Output: DevVoid |
Sets currents unit. |
Pipes:
Properties:
| Name | Description |
|---|---|
| ElectrometerProxyNameDevString | Name of the Electrometer Device proxy (ex : LoCum-4 Device). |
| ElectrometerGainNameDevString | Name of the Electrometer Device gain attribute (ex: gain). |
| SaiControllerProxyNameDevString | Name of the SaiController Device proxy. |
| SaiControllerChan0NameDevString | Name of the SaiController channel 0 attribute (ex: channel0). |
| SaiControllerChan1NameDevString | Name of the SaiController channel 1 attribute (ex: channel1). |
| SaiControllerChan2NameDevString | Name of the SaiController channel 2 attribute (ex: channel2). |
| SaiControllerChan3NameDevString | Name of the SaiController channel 3 attribute (ex: channel3). |
| I1OffsetDevDouble | Current offset (in �A) on electrode 1. |
| I2OffsetDevDouble | Current offset (in �A) on electrode 2. |
| I3OffsetDevDouble | Current offset (in �A) on electrode 3. |
| I4OffsetDevDouble | Current offset (in �A) on electrode 4. |
| GI1DevDouble | Gain correction (in �A/V) for electrode 1. |
| GI2DevDouble | Gain correction (in �A/V) for electrode 2. |
| GI3DevDouble | Gain correction (in �A/V) for electrode 3. |
| GI4DevDouble | Gain correction (in �A/V) for electrode 4. |
| V1OffsetDevDouble | Voltage offset (in V) on electrode 1. |
| V2OffsetDevDouble | Voltage offset (in V) on electrode 2. |
| V3OffsetDevDouble | Voltage offset (in V) on electrode 3. |
| V4OffsetDevDouble | Voltage offset (in V) on electrode 4. |
| LowVoltageThresholdDevDouble | If the input voltage of the ADC decrease this threshold (in V), the corresponding average current attribute become ALARM (i.e. if |Vmes| < threshold). |
| HighVoltageThresholdDevDouble | If the input voltage of the ADC exceed this threshold (in V), the corresponding average current attribute become ALARM (i.e. |Vmes|> threshold). |
| IntensityThresholdDevDouble | Current out of which the Measured Intensity has a meaning (in micro-A). |
| StartAtInitDevBoolean | Launch start command at initialization time. |
| EnableSigmaIntensityDevBoolean | Enables or disables standard deviation intensity computing (standardDeviationIntensity & currentSpectrum attributes). |
| EnablePositionHistoryDevBoolean | Enables or disables standard deviation position computing (standardDeviationPosition & historyPosition attributes) |
| EnableIntensityHistoryDevBoolean | Enables or disables intensity history (historyIntensity attribute) |
| EnableFluxComputingDevBoolean | Enables or disables beam flux display (flux attribute). |
| BeamEnergyProxyNameDevString | Name of the beam Energy Device Proxy. |
| EnergyAttrDevString | Name of the energy attribute to read from the beam energy Device Proxy. |
| ModeXString[]Type | List of the properties needed by the computation mode `X`. Format: {key}::{value} |
| ScanModeDevBoolean | If true, this property enables the scan mode, i.e. the polling task is disabled and data is computed on each client`s request. |
| XbpmTypeDevString | XBPM type among PSD, Quadrant. Determines the intensity calculation. |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:20 Apr 2017, 1:05 p.m.