Class Description
This device server is intended to drive and monitor a ion pump controlled by a Varian Dual ion pump controller. You need VarianDualCrtl device classes OR Agilent4uhv device classes
Families: Vacuum
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: Varian
Product:
Dual IP
Bus: Serial Line
Class interface
Attributes:
| Name | Description |
|---|---|
| PressureScalar: DevFloat | — |
| VoltageScalar: DevFloat | — |
| CurrentScalar: DevFloat | — |
| SizeScalar: DevString | — |
| ControlTypeScalar: DevString | — |
| FirstStepCurrentScalar: DevFloat | — |
| SecondStepCurrentScalar: DevFloat | — |
| FixModeScalar: DevBoolean | — |
| StartModeScalar: DevBoolean | — |
| ControllerScalar: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| OffInput: DevVoid Output: DevVoid |
Set the pump to OFF. |
| OnInput: DevVoid Output: DevVoid |
Set the pump to ON. |
| SetFixedModeInput: DevVoid Output: DevVoid |
Set the pump channel to the "fixed" mode. |
| SetStartModeInput: DevVoid Output: DevVoid |
Set the pump channel to the "start" mode. |
| SetStepModeInput: DevVoid Output: DevVoid |
Set the pump channel to the "step" mode. |
| SetProtectModeInput: DevVoid Output: DevVoid |
Set the pump channel to the "protect" mode. |
Pipes:
Properties:
| Name | Description |
|---|---|
| ChannelNumberDevShort | The channel number of the ion pump (1 or 2) |
| ControllerDeviceNameDevString | The device name of the associated ion pump controller |
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.