This is historical information of device classes implemented in Eurotherm2408 device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Temperature/Eurotherm2408
Contact:
Class Description
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| TemperatureScalar: DevDouble | The current temperature |
| SetpointScalar: DevDouble | The current temperature setpoint |
| ManualScalar: DevBoolean | Manual mode (true = on, false = off) |
| ProgramStateScalar: DevString | Program state. Possible values: reset / run / hold / complete |
| CurrentProgramScalar: DevUShort | Number of the currently running program. |
| CurrentSegmentScalar: DevUShort | Number of the currently running segment. |
| RemainingProgramTimeScalar: DevUShort | Remaining program time in hours |
| RemainingSegmentTimeScalar: DevUShort | Remaining segment time in seconds |
| SegmentTypeScalar: DevString | The type of segment currently running. |
| ProgramDirScalar: DevString | Path to directory containing controller programs |
| MaxProgramsScalar: DevUShort | Maximum number of programs this controller can store. |
| AllowedStatesScalar: DevUChar | Bitmask to set which bits of the controller status byte should not set the device state to ALARM. The status byte bit meaning is: 0: ALARM1 1: ALARM2 2: ALARM3 3: ALARM4 4: MANUAL MODE 5: SENSOR FAILURE 6: LOOP BREAK 7: HEATER FAILURE So to e.g. not cause an alarm state on ALARM1 and MANUAL MODE set the attribute to 17 ( = binary 00010001, bits 0 and 4 => 1). |
| HoldBackScalar: DevBoolean | Report / set holdback state. true = holdback enabled false = holdback disabled |
| OutputLevelScalar: DevDouble | — |
| OutputLevelMaxScalar: DevDouble | — |
| OutputLevelMinScalar: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| StartProgramInput: DevUShort program number Output: DevVoid |
Start a program stored in the controller. The max. program number depends on the hardware, can be 0, 1, 4 or 20. Check with reading attribute MaxPrograms. |
| StopProgramInput: DevVoid Output: DevVoid |
Stop currently running program |
| HoldProgramInput: DevVoid Output: DevVoid |
Hold currently running program |
| LoadProgramInput: DevString path to program file, either absolute or relative to attribute ProgramDir Output: DevVoid |
Loads a program into controller memory |
| DeleteProgramInput: DevUShort Program number Output: DevVoid |
removes program from controller memory |
Pipes:
Properties:
| Name | Description |
|---|---|
| HostNameDevString | Hostname or IP address |
| PortNumberDevString | TCP Port Number. |
| DeviceAddressDevShort | Address of device (adjusted at hardware) |
| SimulationModeDevShort | — |
| LogicOpsDevBoolean | true, if the hardware supports logical operations |
| ConnectTypeDevString | connection type, either `serial` or `net` |
| DeviceFileDevString | tty device file name |
| BaudRateDevLong | tty device baud rate |
README
b'\nbuild the library: \n\n ./Do.pl\n\nmake sure the include files are in \n ~/Tango/Servers/cppserver/include\n'
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.