ScanServerV2 - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released, Release: release_3_3_9
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/SoftwareSystem/Sequencer/ScanServerV2
Contact:



Class Description


This Device is a generic scan service for the Tango world. it allows to move
Actuators (ie writable attributes) and to read Sensors (ie readable attributes) after a specified Integration Time

Families: SoftwareSystem

Key words: - Sequencer

Platform: All Platforms

Language: Cpp

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
dataRecorderPartialModeScalar: DevBoolean —
filePathScalar: DevString —
fileBaseNameScalar: DevString —
fileExtensionScalar: DevString —
runNameScalar: DevString —
pointNumberScalar: DevLong —
pointNumber2Scalar: DevLong —
scanNumberScalar: DevLong —
actuatorsDelayScalar: DevDouble —
timebasesDelayScalar: DevDouble —
manualModeScalar: DevBoolean —
automaticDirectionScalar: DevBoolean —
zigzagScalar: DevBoolean —
onTheFlyScalar: DevBoolean —
hwContinuousScalar: DevBoolean —
hwContinuousNbPtScalar: DevLong —
enableScanSpeedScalar: DevBoolean —
scanTypeScalar: DevLong —
contextValidationScalar: DevString —
contextValidationErrorStrategyScalar: DevLong —
actuatorsTimeOutScalar: DevDouble —
actuatorsRetryCountScalar: DevLong —
actuatorsRetryTimeoutScalar: DevDouble —
actuatorsErrorStrategyScalar: DevLong —
timebasesTimeOutScalar: DevDouble —
timebasesRetryCountScalar: DevLong —
timebasesRetryTimeoutScalar: DevDouble —
timebasesErrorStrategyScalar: DevLong —
sensorsTimeOutScalar: DevDouble —
sensorsRetryCountScalar: DevLong —
sensorsRetryTimeoutScalar: DevDouble —
sensorsErrorStrategyScalar: DevLong —
hooksTimeOutScalar: DevDouble —
hooksRetryCountScalar: DevLong —
hooksRetryTimeoutScalar: DevDouble —
hooksErrorStrategyScalar: DevLong —
afterRunActionTypeScalar: DevLong —
afterRunActionSensorScalar: DevLong —
afterRunActionActuatorScalar: DevLong —
afterRunActionActuatorValueScalar: DevDouble —
runStartDateScalar: DevString —
scanStartDateScalar: DevString —
scanEndDateScalar: DevString —
runEndDateScalar: DevString —
scanDurationScalar: DevString —
runDurationScalar: DevString —
scanRemainingTimeScalar: DevString —
runRemainingTimeScalar: DevString —
scanElapsedScalar: DevString —
runElapsedScalar: DevString —
runCompletionScalar: DevDouble —
scanCompletionScalar: DevDouble —
deadTimeScalar: DevDouble —
deadTimePercentScalar: DevDouble —
deadTimePerPointScalar: DevDouble —
recordDataScalar: DevBoolean —
dataRecordedScalar: DevBoolean —
dataRecorderConfigScalar: DevString —
generatedNexusFileNameScalar: DevString —
versionScalar: DevString —
actuatorsSpectrum: DevString —
actuators2Spectrum: DevString —
sensorsSpectrum: DevString —
timebasesSpectrum: DevString —
integrationTimesSpectrum: DevDouble —
scanSpeedSpectrum: DevDouble —
preRunHooksSpectrum: DevString —
preScanHooksSpectrum: DevString —
preStepHooksSpectrum: DevString —
postActuatorMoveHooksSpectrum: DevString —
postIntegrationHooksSpectrum: DevString —
postStepHooksSpectrum: DevString —
postScanHooksSpectrum: DevString —
postRunHooksSpectrum: DevString —
actuatorsDataListSpectrum: DevString —
actuators2DataListSpectrum: DevString —
sensorsDataListSpectrum: DevString —
scanInfoSpectrum: DevString —
trajectoriesImage: DevDouble —
trajectories2Image: DevDouble —
historicImage: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartInput: DevVoid
Output: DevVoid
Start the Run
AbortInput: DevVoid
Output: DevVoid
Abort the Run
PauseInput: DevVoid
Output: DevVoid
Pause the scan
ResumeInput: DevVoid
Output: DevVoid
Resume the scan when is Pause State
CleanInput: DevVoid
Output: DevVoid
None.
ClearHistoricInput: DevVoid
Output: DevVoid
Empty the log historic
ExecuteActionInput: DevVoid
Output: DevVoid
Executes the specified AfterRunAction

Pipes:

Properties:

Name Description
CurrentFileBaseNameDevString —
ExpertParametersString[]Type —
CurrentFileExtensionDevString —
CurrentFilePathDevString —
DataFileActivationDevBoolean enables the ASCII data file
DataFileTypeDevLong 0 : ASCII 1 : Nexus
DataRecorderDevString device name for the Nexus Data Recorder
DataRecorderWriteModeDevLong 0 -> call WriteScanData in the DataRecorder device 1 -> write nexus file directly from ScanServer
DataRecorderSavingPeriodDevDouble the period (in seconds) at which the DataRecorder->WriteScanData is called
PluginRootPathDevString The path to the plugins directory
DataFitterDevString a data fitter device to use for post scan behavior
SynchronizeDataDevBoolean Enable/Disable synchronize data coming from timebase and sensor. [default = true]
TimeScanActuatorsDelayDevBoolean Set it to `true` if you want to use the `actuatorsdelay` fonctionnality in case of time-scans
NI6602TimebaseDelayDevLong It is sometime needed to insert a delay (ms) before starting a Ni6602 card configured in pulse generator mode


Please log in to comment.

README

b'Introduction\n============\n\nThis is the ScanServer developed at the synchrotron Soleil, France.\nSee the AUTHORS file for a list of the authors of this project.\n\nThe ScanServer is a Tango server which can perform scans of one or many Tango attributes and record the\nsignal of one or many other attributes as a function of the scanned attributes. In order to control\ndata acquisition hardware one or more time bases can be specified which start and stop timers and\ncounters and report when a measurement has been done.\n\nThe automake/autoconf scripts assume the user wants to use NEXUS as a data format. The nexuscpp library is required\nto be installed. The Nexus data format has many advantages over text files and can be red directly by\nmany data analysis programs.\n\nThe main code of the ScanServer functionality is now contained in the ScanUtils library (including PluginGenerator).\n\n\nDirectory Structure (sources)\n=============================\n\n./: the auto-config and auto-make files, README, INSTALL, AUTHORS... files\n./doc: The original documentation from the ScanServerV2.\n./Device: The source code of the ScanServer device\n\n\nDirectory Structure (instaled files)\n====================================\n\n<prefix>/bin: ScanServer binary\n\n\n\n'

20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 11:23 a.m.