Class Description


Class computing vibrations in Petra Hall.

Families: Miscellaneous

Key words:

Platform: Unix Like

Language: Python

License:

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
DeviceScalar: DevString —
DataTypeScalar: DevString —
SampleRateScalar: DevFloat —
TimeOffsetScalar: DevFloat —
OversamplingScalar: DevFloat —
AmpGainScalar: DevFloat —
VTransmissionScalar: DevFloat —
MinFreqScalar: DevFloat —
DeviceTypeScalar: DevString —
MaxFreqScalar: DevFloat —
NDataPointsScalar: DevLong —
TSampleScalar: DevFloat —
NDataPointsSampleScalar: DevLong —
NAverageScalar: DevFloat —
VMeanScalar: DevFloat —
VStdScalar: DevFloat —
RMS1HzScalar: DevDouble —
RMS2HzScalar: DevDouble —
RMS5HzScalar: DevDouble —
RMS10HzScalar: DevDouble —
RMS20HzScalar: DevDouble —
RMS50HzScalar: DevDouble —
TimeAverageScalar: DevDouble —
SumPSDsScalar: DevDouble —
MaxSigScalar: DevDouble —
MinSigScalar: DevDouble —
Time0Scalar: DevString —
LocalTimeScalar: DevString —
CurrentFileNameScalar: DevString —
TimeAxisSpectrum: DevDouble —
FrequenciesSpectrum: DevDouble —
FrequenciesSampleSpectrum: DevDouble —
SSpectrum: DevDouble —
VSpectrum: DevDouble —
ASpectrum: DevDouble —
FftSSpectrum: DevDouble —
FftVSpectrum: DevDouble —
FftASpectrum: DevDouble —
PSDSSpectrum: DevDouble —
PSDVSpectrum: DevDouble —
PSDASpectrum: DevDouble —
RMSSSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.

Pipes:

Properties:

Name Description
FilesPathDevString Path to the directory containing the data from Device.
DeviceDirectionDevString Identify the direction of the device in the room: nord (S1n), east (S1e) or z (S1z).

16 Nov 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 10:59 a.m.