TekDPO7000-ds - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Tektronix/TekDPO7000-ds
Contact:



Class Description


Device server designed to control the tektronix`s oscilloscopes model DPO7254

Families: MeasureInstruments

Key words: Tektronix

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
HOffsetScalar: DevShort —
HScaleScalar: DevDouble —
DelayScalar: DevShort —
ImpedanceCh1Scalar: DevDouble —
CurrentSampleRateScalar: DevDouble —
VScaleCh1Scalar: DevDouble —
VScaleCh2Scalar: DevDouble —
VScaleCh3Scalar: DevDouble —
VScaleCh4Scalar: DevDouble —
ImpedanceCh2Scalar: DevDouble —
ImpedanceCh3Scalar: DevDouble —
ImpedanceCh4Scalar: DevDouble —
ResolutionScalar: DevLong —
AmplitudeCh1Scalar: DevDouble —
AmplitudeCh2Scalar: DevDouble —
AmplitudeCh3Scalar: DevDouble —
AmplitudeCh4Scalar: DevDouble —
RiseCh1Scalar: DevDouble —
RiseCh2Scalar: DevDouble —
RiseCh3Scalar: DevDouble —
RiseCh4Scalar: DevDouble —
JitRMSCh1Scalar: DevDouble —
JitRMSCh2Scalar: DevDouble —
JitRMSCh3Scalar: DevDouble —
JitRMSCh4Scalar: DevDouble —
VOffsetCh1Scalar: DevDouble —
VOffsetCh2Scalar: DevDouble —
VOffsetCh3Scalar: DevDouble —
VOffsetCh4Scalar: DevDouble —
VOffsetSpectrum: DevDouble —
VScaleSpectrum: DevDouble —
Channel1Spectrum: DevDouble —
Channel2Spectrum: DevDouble —
Channel3Spectrum: DevDouble —
Channel4Spectrum: DevDouble —
ImpedancesSpectrum: DevDouble —
ChannelsImage: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
ResetInput: DevVoid
Output: DevVoid
None.
StartInput: DevVoid
Output: DevVoid
None.
StopInput: DevVoid
Output: DevVoid
None.
IDNInput: DevVoid
Output: DevString
Basic command used to validate the comunication. It send the `*IDN?` command-string to the (remote) instrument, and the instrument respond basic data about itself.
CMDInput: DevString
Output: DevString
This command sends the input string as a command to the device, and it returns the string that the device returns.
OnInput: DevShort
Output: DevVoid
None.
OffInput: DevShort
Output: DevVoid
None.

Pipes:

Properties:

Name Description
NumChannelsDevShort This information is used to generate dinamically the number of spaces will be in much of the spectrum values.
IPDevString —


Please log in to comment.

20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 10:31 a.m.