Class Description
Device Server for Keithley voltmeter
Families: MeasureInstruments
Key words: Keithley
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| DCVoltageScalar: DevDouble | — |
| PLCScalar: DevDouble | — |
| DCRangeScalar: DevDouble | — |
| TriggerDelayScalar: DevLong | — |
| TriggerCountsScalar: DevLong | — |
| DigitsScalar: DevUShort | — |
| EnableAutozeroScalar: DevBoolean | — |
| BufferPointsScalar: DevLong | — |
| BufferedVoltageSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
It start a new acquisition. |
| StopInput: DevVoid Output: DevLong |
It stops the current acquisition. if 0 Full buffer, No trigger lost. if 1-9 Full buffer, Number of trigger lost. if 100 No Full buffer, No trigger lost. if 101-109 No Full buffer, Number of trigger lost. |
| ResetInput: DevVoid Output: DevVoid |
It resets the device. |
| GetErrorInput: DevVoid Output: DevVoid |
None. |
| WriteReadInput: DevString Output: DevString |
if the last cmd-character is `?` we check for answer. |
| SetTimerTriggerInput: DevDouble Output: DevVoid |
Select the Timer as the Trigger source and set the timer Interval (In seconds). |
| SetExtTriggerInput: DevVoid Output: DevVoid |
Select an external trigger as source of trigger. |
| SetLinkTriggerInput: DevVoid Output: DevVoid |
None. |
| DownloadBufferInput: DevVoid Output: DevVoid |
None. |
| SetFilterInput: DevLong Output: DevVoid |
Filter counts. If 0 filter off, from 1 to 100 filter on. |
| SetTimestampsOnInput: DevVoid Output: DevVoid |
Only for Keithely 2001. We store the timestamps in the Keithley and in the data file. No voltages! |
| SetTimestampsOffInput: DevVoid Output: DevVoid |
Only for Keithely 2001. We don`t store the timestamps. Only the voltages! |
| IncludeReadingInput: DevVoid Output: DevVoid |
It includes reading in data string. |
| EnableRAVInput: DevVoid Output: DevVoid |
Measurement event register: reading available. |
Pipes:
Properties:
| Name | Description |
|---|---|
| DeviceNameDevString | This is the serial (or Gpib) line device exported by Serial (or Gpib) Server that will be controlled. |
| SerialLineControlledDevBoolean | If set to TRUE, a serial line controller will be used. Otherwise, the gpib interface will be used. |
| ModelDevString | This is the Keithley model. It can be `2001` or `2010`. |
| MemoryDevLong | The number of bytes that we download from keithley-memory. For Keithley `2010` is 1024. For Keithley `2001` is 30000. |