Keithley6517a - - TANGO Controls

This is historical information of device classes implemented in Keithley6517a device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Keithley/Keithley6517a
Contact:



Class Description


Class for controlling the Keithley6517a electrometer

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Keithley

Product:

6517a

Bus: GPIB

Class interface


Attributes:

Name Description
CurrentScalar: DevDouble Measured current
RangeScalar: DevDouble —
MeasurementFunctionScalar: DevString Set/get measurement function. Valid values: VOLT, CURR, RES, CHAR
VoltIntegrationPeriodScalar: DevDouble Integration period for voltage measurements.
CurrIntegrationPeriodScalar: DevDouble Integration period for current measurements.
CharIntegrationPeriodScalar: DevDouble Integration period for charge measurements.
VoltRangeScalar: DevDouble Measurement range for Volts
CurrRangeScalar: DevDouble Measurement range for Amps
CharRangeScalar: DevDouble Measurement range for Coulombs
VSourceScalar: DevDouble V-Source level for manual V-source Ohms.
ResIntegrationPeriodScalar: DevDouble Integration period for resistance measurements.
VSourceOffOnScalar: DevLong Enable/disable (1/0) V-Source level for manual V-source Ohms.
CurrAutoRangeScalar: DevLong 1 -> ON, 0 -> OFF
VoltAutoRangeScalar: DevLong 1 -> ON, 0 -> OFF
CharAutoRangeScalar: DevLong 1 -> ON, 0 -> OFF
CurrRange20mAScalar: DevLong 1 if current range 20 mA
CurrRange2mAScalar: DevLong 1 if current range 2 mA
CurrRange200microAScalar: DevLong 1 if current range 200 microA
CurrRange20microAScalar: DevLong 1 if current range 20 microA
CurrRange2microAScalar: DevLong 1 if current range 2 microA
CurrRange200nAScalar: DevLong 1 if current range 200 nA
CurrRange20nAScalar: DevLong 1 if current range 20 nA
CurrRange2nAScalar: DevLong 1 if current range 2 nA
CurrRange200pAScalar: DevLong 1 if current range 200 pA
CurrRange20pAScalar: DevLong 1 if current range 20 pA
ZeroCheckScalar: DevLong 0 -> off, 1 -> on
CurrentWithTimestampSpectrum: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
State Code
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Status description
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller.
ResetTimestampInput: DevVoid
Output: DevVoid
Reset timestamp to 0

Pipes:

Properties:

Name Description
GpibDeviceDevString Name of the gpib device connected to the hardware.

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 10:26 a.m.