This is historical information of device classes implemented in Keithley2000 device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/Keithley/Keithley2000
Contact:



Class Description


Class for controlling Keithley 2000 devices

Families: Instrumentation

Key words:

Platform: Unix Like

Language: Cpp

License:

Contact:

Hardware


Manufacturer: Keithley

Product:

2000

Bus: GPIB

Class interface


Attributes:

Name Description
MeasurementFunctionScalar: DevString Set the instrument for measuring in the selected function. Get the function selected for measurements. Posible values are: CURR (DC current), VOLT (DC voltage), RES (2-wire resistance) , FRES (4-wire resistance).
CurrIntegrationPeriodScalar: DevDouble Integration period in number of power line cycles.
VoltIntegrationPeriodScalar: DevDouble Integration period in number of power line cycles.
ResIntegrationPeriodScalar: DevDouble Integration period in number of power line cycles.
FResIntegrationPeriodScalar: DevDouble Integration period in number of power line cycles.
CurrRangeScalar: DevDouble Measurement range for the measurement function. The range is selected by specifying the expected reading as an absolute value. The Keithley will go to the most sensitive range that will accomodate the expected reading.
VoltRangeScalar: DevDouble Measurement range for the measurement function. The range is selected by specifying the expected reading as an absolute value. The Keithley will go to the most sensitive range that will accomodate the expected reading.
ResRangeScalar: DevDouble Measurement range for the measurement function. The range is selected by specifying the expected reading as an absolute value. The Keithley will go to the most sensitive range that will accomodate the expected reading.
FResRangeScalar: DevDouble Measurement range for the measurement function. The range is selected by specifying the expected reading as an absolute value. The Keithley will go to the most sensitive range that will accomodate the expected reading.
MeasuredValueScalar: DevDouble Result of the measurement

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
GpibDeviceDevString Name of the Gpib Tango device connecting to the hardware

23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.