SQLServer - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: New development
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Communication/SQLServer
Contact:



Class Description


Device Server for SQLServer Database Access
This device requires Fandango module to be available in the PYTHONPATH.

Families: Communication

Key words:

Language: Python

License:

Contact:

Class interface


Attributes:

Name Description
LastUpdateScalar: DevString

Commands:

Name Description
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
QueryInput: DevString
Output: DevVarStringArray
None.

Pipes:

Properties:

Name Description
HostDevString SQLServer host
DataBaseDevString SQL database
DBTypeDevString SQLServer or MySQL
PortDevString SQLServer port
UserDevString
PasswordDevString
UseLocalTimeDevBoolean


Please log in to comment.

Generated

PDF generated from POGO



README

b'=======================\nSQLServer Device Server\n=======================\n\nDescription\n-----------\n\nDevice Server for SQLServer Database Access\n\nDeveloped at ALBA by Sergi Rubio: http://www.tango-controls.org/Members/srubio\nThis device server requires fandango: http://www.tango-controls.org/Documents/tools/fandango\nIt is based on DynamicAttributes: http://www.tango-controls.org/howtos/dynamicattributes\n\n\nUsage\n-----\n\nTo use the device you must initialize the following properties: \n\n Host, Port, DataBase, User, Password\n\n\nThen, you can use the device directly executing the Query() command:\n\n value1 = PyTango.DeviceProxy(\'my/sql/server\').Query("select TOP 1 value from db.table1 where name in (\'value1\') order by ts DESC")</pre>\n\n\nOr create a DynamicAttributes property that read attribute values from the database using the QUERY keyword:\n\n Value1=QUERY("select TOP 1 value from db.table1 where name in (\'value1\') order by ts DESC")[0][0]\n\n\nYou can define intermediate variables to have shorter syntax or string substitution:\n\n QLAST=str("select TOP 1 value from db.table1 where name in (\'%s\') order by ts DESC")\n Value1=QUERY(str(QLAST)%\'Value1\')[0][0]</pre>\n\n\nThe T_ATTR keyword allows to set both timestamp and value for the attribute from a time,value row:\n\n Value1=DevDouble(T_ATTR(QUERY("select TOP 1 ts,value from db.table1 where name in (\'value1\') order by ts DESC")[0]))\n'

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:54 a.m.