Class Description
Device to ...
Families: Calculation
Key words:
Platform: All Platforms
Language: Python
Contact: sblanch@cells.es
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
FilledBunchesScalar: DevShort | — |
OffsetHScalar: DevDouble | Oscilloscope Horizontal Offset |
OffsetH_expertScalar: DevDouble | Oscilloscope Horizontal Offset |
ScaleHScalar: DevDouble | Oscilloscope Horizontal Scale |
ScaleH_expertScalar: DevDouble | Oscilloscope Horizontal Scale |
SpuriousBunchesScalar: DevShort | — |
StartingPointScalar: DevShort | — |
StartingPoint_expertScalar: DevShort | — |
ThresholdScalar: DevDouble | — |
Threshold_expertScalar: DevDouble | — |
TimingTriggerScalar: DevShort | — |
TimingTrigger_expertScalar: DevShort | — |
emitCyclicBufferScalar: DevBoolean | This boolean attribute is to allow or not to emit the events on the cyclic Buffer. This is because it can cause delay dou to be too big buffer |
nAcquisitionsScalar: DevUShort | Number of elements in the cyclic buffer from where the calculation takes the data. |
nBunchesScalar: DevShort | — |
resultingFrequencyScalar: DevDouble | Expert attribute to read the frequency with this device is pushing results in the output |
CurrentSampleRateScalar: DevDouble | — |
BunchIntensitySpectrum: DevDouble | — |
CyclicBufferTraceSpectrum: DevString | Internal use attribute to have information about how the buffer changes |
InputSignalSpectrum: DevDouble | — |
cyclicBufferImage: DevDouble | Expert attribute to be able to check the cyclic buffer evolution |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartInput: DevVoid Output: DevVoid |
— |
StopInput: DevVoid Output: DevVoid |
— |
ExecInput: DevString statement to executed Output: DevString result |
— |
Pipes:
Properties:
Name | Description |
---|---|
AutoStartDevBoolean | Configure if the device must start the calculation by default when it is launched |
FCTAttributeDevString | Channel of the scope from where the readings are get |
RfGeneratorAttrDevString | RfGenerator Attr name from where the frequency is read from time to time |
RfGeneratorDevDevString | RfGenerator Device name from where the frequency is read from time to time |
dcctAttrDevString | DCCT Attr name from where the sr current is read from time to time |
dcctDevDevString | DCCT Device name from where the sr current is read from time to time |
erDevDevString | Event Receiver Device name |
scoDevDevString | Scope Device name where one channel has the FCT signal |
Class Description
Device to ...
Families: Calculation
Key words:
Platform: All Platforms
Language: Python
Contact: sblanch@cells.es
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Name | Description |
---|---|
ThresholdScalar: DevUShort | — |
Threshold_expertScalar: DevUShort | — |
resultingFrequencyScalar: DevDouble | Expert attribute to read the frequency with this device is pushing results in the output |
nBunchesScalar: DevShort | — |
SpuriousBunchesScalar: DevShort | — |
FilledBunchesScalar: DevShort | — |
nAcquisitionsScalar: DevUShort | Number of elements in the cyclic buffer from where the calculation takes the data. |
BunchIntensitySpectrum: DevDouble | — |
InputSignalSpectrum: DevDouble | — |
Commands:
Name | Description |
---|---|
StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
StartInput: DevVoid Output: DevVoid |
— |
StopInput: DevVoid Output: DevVoid |
— |
ExecInput: DevString statement to executed Output: DevString result |
— |
Pipes:
Properties:
Name | Description |
---|---|
PhCtDevDevString | Photon Counter device name |
AutoStartDevBoolean | Configure if the device must start the calculation by default when it is launched |
PhCtAttrDevString | Photon Counter histogram property name |
dcctAttrDevString | DCCT Attr name from where the sr current is read from time to time |
dcctDevDevString | DCCT Device name from where the sr current is read from time to time |
Updated:
A device class has been added.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.