AttenFactorCalc - - TANGO Controls

This is historical information of device classes implemented in AttenFactorCalc device server.

Use this link to find the valid information.

Development status: Released
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Calculation/AttenFactorCalc
Contact:



Class Description


Class for conmputing attenuator factors.

Families: Calculation

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
PositionScalar: DevDouble —
FlagSlaveScalar: DevLong 0 -> not slave from monochromator energy device, energy fixed
AbsDeviceScalar: DevString Name of the AbsorberDevice defined in the online.xml file as abs.
Foil1Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil2Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil3Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil4Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil5Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil6Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil7Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil8Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil9Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil10Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil11Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
Foil12Scalar: DevDouble Attenuation factor computed/written by external program if FlagSlave is 0, or internally from the monochromator energy otherwise.
AttenDeziScalar: DevDouble Value of the Attribute Position of the AbsorberController tango device
AttenFactorScalar: DevDouble Attenuation factor computed inside the Tango Server.
PositionSimScalar: DevDouble —
AttenBitsSpectrum: DevLong Attribute SlidersIn from AbsorberController in bits
ResultSimSpectrum: DevString —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
MonochromatorDeviceNameDevString Name of the monochromator tango device
AbsorberControllerDeviceNameDevString Name of the AbsorberController device to be used.
FoilDataDirectoryDevString Directory containing the data with the foil information

15 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You are looking at this version now.



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 9:38 a.m.