This is historical information of device classes implemented in FMBOxfDCMCtrl device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamlineComponents/Monochromators/FMBOxfDCMCtrl
Contact:
Class Description
Class connecting to the Double Crystal Monochrometor Drive from FMB Oxford via RS232
Families: Motion
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Serial Line
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| WriteAdrPortInput: DevString Command Output: DevVoid |
Send a command to the RS232 port. |
| WriteReadAdrPortInput: DevString Command Output: DevString Answer |
Write a command and get an answer. |
| CloseAdrPortInput: DevVoid Output: DevVoid |
Close port connection. |
| StopMovesInput: DevVoid Output: DevVoid |
Send CTRL-A for stopping all movements. |
Pipes:
Properties:
| Name | Description |
|---|---|
| PortNbDevLong | RS232 Port Number |
| IpAddrDevString | Ip address of the terminal server |
| SimulationModeDevULong | 0 -> real mode, 1 -> simulation mode |
README
b'\nbuild the library: \n\n ./Do.pl\n\nmake sure the include files are in \n ~/Tango/Servers/sppserver/include\n'
Updated:
The device class has been updated.
You are looking at this version now.
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.