.
Development status:
New development
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/BeamDiagnostics/LiberadbControl
Contact:
Class Description
- This device server allows an easy access to the libera configuration parameters in the database. Any change in the attribute values is stored
- in the dabase. A command is provided to reaload the parameters from the datasbase (ReloadDb). This server maps any libera device parameter to an attribute.
Families: BeamDiagnostics
Key words:
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| Q_OFFSET_1Scalar: DevDouble | — |
| A_OFFSET_EScalar: DevDouble | — |
| B_OFFSET_EScalar: DevDouble | — |
| C_OFFSET_EScalar: DevDouble | — |
| D_OFFSET_EScalar: DevDouble | — |
| X_OFFSET_1Scalar: DevDouble | — |
| X_OFFSET_2Scalar: DevDouble | — |
| Z_OFFSET_1Scalar: DevDouble | — |
| Z_OFFSET_2Scalar: DevDouble | — |
| Q_OFFSET_2Scalar: DevDouble | — |
| A_OFFSET_CScalar: DevDouble | — |
| B_OFFSET_CScalar: DevDouble | — |
| C_OFFSET_CScalar: DevDouble | — |
| D_OFFSET_CScalar: DevDouble | — |
| X_OFFSET_3_FTScalar: DevDouble | — |
| X_OFFSET_3_TTScalar: DevDouble | — |
| X_OFFSET_3_BNScalar: DevDouble | — |
| X_OFFSET_4Scalar: DevDouble | — |
| X_OFFSET_5Scalar: DevDouble | — |
| Z_OFFSET_3_FTScalar: DevDouble | — |
| Z_OFFSET_3_TTScalar: DevDouble | — |
| Z_OFFSET_3_BNScalar: DevDouble | — |
| Z_OFFSET_4Scalar: DevDouble | — |
| Z_OFFSET_5Scalar: DevDouble | — |
| KxScalar: DevDouble | — |
| KzScalar: DevDouble | — |
| NSamplesScalar: DevLong | — |
| Attenuator1Scalar: DevShort | — |
| Attenuator2Scalar: DevShort | — |
| LiberaDeviceNameStrScalar: DevString | — |
| LiberaDeviceNumberScalar: DevShort | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ReloadDbInput: DevVoid Output: DevVoid |
When this command is executed, the libera device executes the function "Init", so the new values from the database are realoaded to the device |
Pipes:
Properties:
| Name | Description |
|---|---|
| LiberaDeviceNameDevString | The libera device which parameters will be changed [No default value] |
Please log in to comment.
Generated
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:23 Feb 2017, 9:25 a.m.