Average: 0
Rating Count: 0

Development status: New development
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/NI/ImgAnalogGrabber
Contact:



Class Description


The device grabs images from a NI1409 acquisition board

Families: Acquisition

Key words: - 2D

Language: Cpp

License:

Contact:

Class interface


Attributes:

Name Description
ImageImage: DevShort
RefreshingPeriodScalar: DevDouble
ExposureTimeScalar: DevDouble
ShutterDelayScalar: DevDouble
WhiteRefLevelScalar: DevDouble
BlackRefLevelScalar: DevDouble
ModeScalar: DevUShort
ActiveChannelScalar: DevUShort

Commands:

Name Description
ToggleImageFreezingInput: DevVoid
Output: DevVoid
None.
StopInput: DevVoid
Output: DevVoid
stops the video acquisition
StartInput: DevVoid
Output: DevVoid
launch the image acquisition
CloseInput: DevVoid
Output: DevVoid
closes and unlock the video interface
OpenInput: DevVoid
Output: DevVoid
opens and locks the hardware interface
SaveCurrentSettingsInput: DevVoid
Output: DevVoid
saves the current configuration parameters to the Tango database
GetROIInput: DevVoid
Output: DevVarULongArray
gives the current ROI used
FullROIInput: DevVoid
Output: DevVoid
resets any previously specified ROI
SetROIInput: DevVarULongArray
Output: DevVoid
specify a Region Of Interest in the image
AutoAdjustRefLevelsInput: DevVoid
Output: DevVoid
auto adjust the white reference level to adapt the dynamic of the image to the resolution
StatusInput: DevVoid
Output: DevString
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StateInput: DevVoid
Output: State
This command gets the device state (stored in its device_state data member) and returns it to the caller.

Pipes:

Properties:

Name Description
AutoStartDevBoolean
UseAsyncGrabbingDevBoolean
InterfaceNameDevString
Channel3SoftTrigPeriodDevDouble
Channel3ShutterExposureDevDouble
Channel3ShutterDelayDevDouble
Channel3RefLevelWhiteDevDouble
Channel3RefLevelBlackDevDouble
Channel3ModeDevShort
Channel2SoftTrigPeriodDevDouble
Channel2ShutterExposureDevDouble
Channel2ShutterDelayDevDouble
Channel2RefLevelWhiteDevDouble
Channel2RefLevelBlackDevDouble
Channel2ModeDevShort
Channel1SoftTrigPeriodDevDouble
Channel1ShutterExposureDevDouble
Channel1ShutterDelayDevDouble
Channel1RefLevelWhiteDevDouble
Channel1RefLevelBlackDevDouble
Channel1ModeDevShort
Channel0SoftTrigPeriodDevDouble
Channel0ShutterExposureDevDouble
Channel0ShutterDelayDevDouble
Channel0RefLevelWhiteDevDouble
Channel0RefLevelBlackDevDouble
Channel0ModeDevShort
ActiveChannelDevShort


Please log in to comment.

22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



16 Feb 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:23 Feb 2017, 10:16 a.m.