This is historical information of device classes implemented in Deditek device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Class to controll a Deditek USB-OPTOIN-8 IO module
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: DEDITEC
Product:
Bus: USB
Class interface
Attributes:
| Name | Description |
|---|---|
| OutletScalar: DevBoolean | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
Pipes:
Properties:
| Name | Description |
|---|---|
| OutletNrDevULong | Number of outlet on modules |
| ModuleNrDevULong | Number of connected module |
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.