This is historical information of device classes implemented in BronkhorstMassFlowCtrl device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Class talking to the Bronkhorst Mass Flow device using the FlowBus protocol,
Families: Instrumentation
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: Bronkhorst
Product:
Mass Flow
Bus: USB
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| WriteReadUSBInput: DevString String to write Output: DevLong Output Value |
Write to the USB device and return an answer. |
Pipes:
Properties:
| Name | Description |
|---|---|
| TerminalPortDevString | Name of the device in /dev |
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.