AXISCamera - - TANGO Controls

This is historical information of device classes implemented in AXISCamera device server.

Use this link to find the valid information.

Development status: Released, Release: Release_1_2
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/AXISCamera
Contact:



Class Description


Server to get image from AXIS Dome cameras

Families: Acquisition

Key words:

Platform: All Platforms

Language: PythonHL

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: Not Applicable

Class interface


Attributes:

Name Description
ResolutionModeScalar: DevLong —
AvailableResolutionsScalar: DevString —
FrameTimeScalar: DevDouble —
FrameTimeStrScalar: DevString —
FPSLimitScalar: DevLong —
CurrentFPSScalar: DevDouble —
PanScalar: DevDouble —
TiltScalar: DevDouble —
ZoomScalar: DevLong —
IrisScalar: DevLong —
FocusScalar: DevLong —
BrightnessScalar: DevLong —
AutoFocusScalar: DevBoolean —
MaxPanScalar: DevDouble —
MinPanScalar: DevDouble —
MaxTiltScalar: DevDouble —
MinTiltScalar: DevDouble —
MaxZoomScalar: DevLong —
MinZoomScalar: DevLong —
MaxFocusScalar: DevLong —
MinFocusScalar: DevLong —
LastFrameNumberScalar: DevLong —
ImageRGBImage: DevLong —
ImageGrayscaleImage: DevDouble —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcquisitionInput: DevVoid
Output: DevVoid
—
StopAcquisitionInput: DevVoid
Output: DevVoid
—
StartAcquisitionOnceInput: DevVoid
Output: DevVoid
—

Pipes:

Properties:

Name Description
UserDevString —
PasswordDevString —
HostDevString —

README

b'# AXISCamera server\r\n\r\n###General info:\r\nThis is small server to acquire image from AXIS Dome cameras and control camera position\r\n\r\nServer can login to the camera, if username and password are provided. Alternative, you should enable anonymous login frame view and PZT control in camera settings \r\n\r\nThe server is better to use with the PetraViewer utility.\r\n\r\n###Properties:\r\nHost: host of the camera\r\n\r\nUser: username for login\r\n\r\nPassword: password for login\r\n\r\n###Operation:\r\n\r\nAfter start, server tries to automatically find the available resolutions and movement limits.\r\n\r\nThe found resolutions are displayed in AvailableResolutions attribute and can be selected by ResolutionMode attribute. The mode 0 is the highest possible resolution, the modes 1, 2, etc - are the next lower one\r\n\r\nTo start frame view execute StartAcquisition command. To limit FPS set FPSLimit attribute. FPSLimit=0 means unlimited FPS\r\n\r\nThe frames are available by ImageGrayscale or ImageRGB attributes, where ImageRGB is converted to 32bit integer RBG pixel. \r\n'

3 Sep 2022, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



20 Aug 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Aug 2022, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:3 Sep 2022, 2:44 a.m.