This is historical information of device classes implemented in VFCADC device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Server for a VFC ADC. The Server describes a channel.
Families: InputOutput
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: VME
Class interface
Attributes:
| Name | Description |
|---|---|
| ValueScalar: DevDouble | ADC value |
| GainScalar: DevDouble | — |
| OffsetScalar: DevDouble | — |
| PolarityScalar: DevLong | — |
| CountsScalar: DevLong | — |
| FlagVFCADCInitScalar: DevBoolean | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| ResetInput: DevVoid Output: DevLong completion status |
Reset a channel, clear contents. |
| SetGainInput: DevVoid Output: DevLong completion status |
Set gain in ADC to Gain value. |
| SetPolarityInput: DevVoid Output: DevLong completion status |
Set polarity in ADC to Polarity value. |
| SetOffsetInput: DevVoid Output: DevLong completion status |
Set offset in ADC to Offset value. |
| InitVFCADCInput: DevVoid Output: DevLong completion status |
Init VFCADC. Set FlagVFCADCInit |
Pipes:
Properties:
| Name | Description |
|---|---|
| BaseDevULong | VME base address. Default value 0x011000 (in decimal 69632) |
| ChannelDevULong | Channel number. Each module has 8 channels. |
| SimulationModeDevULong | 0 real mode, 1 simulation mode |
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2
on:19 Jan 2017, 10:41 a.m.