This is historical information of device classes implemented in MaiaMetadata device server.
Use this link to find the valid information.
Development status:
Released
Information status: New
Contact:
Class Description
Class containing metadata for the Maia Detector
Families: Acquisition
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: Brookhaven National Laboratory and Commonwealth Scientific and Industrial Research Organisation
Product:
Maia Detector
Bus: Data Socket
Class interface
Attributes:
| Name | Description |
|---|---|
| BeamEnergyScalar: DevDouble | — |
| SampleInfoScalar: DevString | — |
| SampleNameScalar: DevString | — |
| SampleOwnerScalar: DevString | — |
| SampleSerialScalar: DevString | — |
| ScanCrossrefScalar: DevString | — |
| ScanDwellScalar: DevDouble | — |
| ScanInfoScalar: DevString | — |
| ScanOrderScalar: DevString | — |
| ScanRegionScalar: DevString | — |
| ScanSequenceNumberScalar: DevLong | — |
| ScanSequenceTotalScalar: DevLong | — |
| KeysSpectrum: DevString | User-definde metadata keys. |
| ValuesSpectrum: DevString | Values for the user-defined metadata. |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| SetKeyInput: DevVarLongStringArray Index number and metadata key. Output: DevVoid |
Set the input string to the key of the metadata in the given index. |
| SetValueInput: DevVarLongStringArray Index number and metadata value. Output: DevVoid |
Set the input string to the value of the metadata in the given index. |
| GetMetadataInput: DevLong Index Output: DevString Key: Value |
Returns key and value of the metadata in the input index |
Pipes:
Properties:
| Name | Description |
|---|---|
| SocketDSDevString | Name of the tango device making the socket connection (MaiaCtrl) |
| SimulationModeDevLong | 1 if in simulation mode |
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You are looking at this version now.
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.