This is historical information of device classes implemented in SRSCurrentPreampSR570 device server.
Use this link to find the valid information.
Development status:
New development
Information status: Updated
Contact:
Class Description
SRS Current Preamplifier SR570
Families: MeasureInstruments
Key words:
Platform: Unix Like
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: Standord Research Systems
Product:
SR570
Bus: Serial Line
Class interface
Attributes:
| Name | Description |
|---|---|
| SensitivityScalar: DevLong | — |
| SensitivityCalModeScalar: DevLong | 0 -> cal 1 -> uncal |
| SensitivityCalVernierScalar: DevLong | Percentage from full scale |
| InputOffsetOffOnScalar: DevLong | 0 -> off 1 -> on |
| InputOffsetLevelScalar: DevLong | — |
| InputOffsetSignScalar: DevLong | 0 -> neg 1 -> pos |
| InputOffsetCalModeScalar: DevLong | 0 -> cal 1 -> uncal |
| InputOffsetCalVernierScalar: DevLong | 0 to +/-100% of full scale |
| BiasOffOnScalar: DevLong | 0 -> off 1 -> on |
| BiasLevelScalar: DevLong | — |
| FilterTypeScalar: DevLong | 0 -> 6 dB highpass 1 -> 12 dB highpass 2 -> 6 dB bandpass 3 -> 6 dB lowpass 4 -> 12 dB lowpass 5 -> none |
| LPFilterFreqScalar: DevLong | — |
| HPFilterFreqScalar: DevLong | — |
| GainModeScalar: DevLong | 0 Low Noise 1 High Bandwidth 2 Low Drift |
| InvertScalar: DevLong | 0 non-inverted 1 inverted |
| BlankScalar: DevLong | 0 no blank 1 blank |
| SensitivityPhysicalScaleScalar: DevString | 0 1 2 - > 1 2 5 pA/V 3 4 5 -> 10 20 50 pA/V 6 7 8 -> 100 200 500 pA/V 9 10 11 -> 1 2 5 nA/V 12 13 14 -> 10 20 50 nA/V 15 16 17 -> 100 200 500 nA/V 18 19 20 -> 1 2 5 µA/V 21 22 23 -> 10 20 50 µA/V 24 25 26 ->100 200 500 µA/V 27 ->1 mA/V |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ResetFilterInput: DevVoid Output: DevVoid |
resets filter capacitors to clear an overload condition |
| ResetAllInput: DevVoid Output: DevVoid |
resets the amplifier to default settings |
Pipes:
Properties:
| Name | Description |
|---|---|
| IPAddressDevString | IP Address in case the connection is done via Ethernet |
| PortNbDevLong | Port number in case the connection is done via Ethernet |
| SerialPortDevString | Serial port with the rs232 connection, e.g. /dev/ttyUSB0. |
Updated:
The device class has been updated.
You can see previous version here .
16 Oct 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
31 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
10 Jul 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
3 Jul 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
19 Jun 2021, DS Admin
Created:
The device class has been added to catalogue.