This is historical information of device classes implemented in Modbus device server.
Use this link to find the valid information.
Development status:
Released,
Release: release_3_7_2
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Communication/Modbus
Contact:
Class Description
A Class to handle the modbus protocol over TCP/IP or Serial (RTU).
Families: Communication
Key words:
Platform: All Platforms
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Modbus
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ForceSingleCoilInput: DevVarShortArray aring[0] = coil address argin[1] = coil value (0/1) Output: DevVoid |
Write single coil (digital I/O) state. |
| ReadCoilStatusInput: DevShort Coil address Output: DevShort Coil status (0/1) |
Read coil (digital I/O) status |
| ReadInputStatusInput: DevVarShortArray argin[0] = Input address argin[1] = number of inputs Output: DevVarCharArray argout[0..n-1] = Input status (0/1) |
Read discrete input status. Return one boolean per array element. |
| ReadHoldingRegistersInput: DevVarShortArray aring[0] = Register start address argin[1] = Number of registers Output: DevVarShortArray argout[0..n-1] Holding 16bits registers. |
Read multiple 16bits registers. |
| ReadInputRegistersInput: DevVarShortArray argin[0] = Register start address argin[1] = Number of registers Output: DevVarShortArray argout[0..n-1] = Input 16bits registers |
Read Multiple 16bits input registers. |
| PresetSingleRegisterInput: DevVarShortArray argin[0] = Register address argin[1] = Register value Output: DevVoid |
Write single 16bits register. |
| FetchCommEventCtrInput: DevVoid Output: DevVarShortArray argout[0] = Status argout[1] = Event count |
Fetch communications event counter. |
| ForceMultipleCoilsInput: DevVarShortArray argin[0] = Coil start address argin[1] = Number of coil argin[2..n+1] = Coil values Output: DevVoid |
— |
| ReadMultipleCoilsStatusInput: DevVarShortArray argin[0] = Coil start address argin[1] = Number of coils Output: DevVarShortArray argout[0..n-1] = Coil values |
Read multiple coil (digital I/O) status. |
| PresetMultipleRegistersInput: DevVarShortArray argin[0] = Register start address argin[1] = Number of register argin[2..n+1] = Register values Output: DevVoid |
Write multiple 16bits registers. |
| MaskWriteRegisterInput: DevVarShortArray argin[0] = Register address argin[1] = AND mask argin[2] = OR mask Output: DevVoid |
Mask write a 16bits register. |
| ReadWriteRegisterInput: DevVarShortArray argin[0] = Read start address argin[1] = Number of registers to read argin[2] = Write start address argin[3] = Number of registers to write argin[4..n+3] = Register values Output: DevVarShortArray argout[0..n-1] = Register values |
Read and Write multiple 16bits registers. |
| PresetSingleRegisterBroadcastInput: DevVarShortArray argin[0] = Register address argin[1] = Register value Output: DevVoid |
Write single 16bits register at node 0 (Node reserved for broadcast for RTU protocol on RS485 line) Does not wait for the equipment response. |
| ReadExceptionStatusInput: DevVoid Output: DevShort Exception status |
Read exception status (usually a predefined range of 8 bits |
Pipes:
Properties:
| Name | Description |
|---|---|
| ProtocolDevString | RTU => Binary serial communication. TCP => Communication over ethernet. |
| IphostDevString | The host IP address used with the TCP protocol |
| SeriallineDevString | The name of the serial line device used with RTU protocol |
| AddressDevShort | Node index used with the RTU or TCP protocol |
| CacheConfigArray of DevString | Describe which data has to be cached. Each set of cached data is described by 3 parameters which are: 1 - Command to be used to read data (ReadHoldingRegisters, ReadInputStatus ReadInutRegisters or ReadMultipleCoilStatus) 2 - First address to be read 3 - Number of data to read |
| CacheSleepDevLong | Cache update thread main loop sleeping time (in ms)CacheSleep |
| TCPConnectTimeoutDevDouble | TCP connection timeout (in sec) |
| TCPTimeoutDevDouble | Timeout used when the TCP protocol is used (in sec) |
| LogFileDevString | Name of the file where are stored invalid frame |
| TCPNoDelayDevBoolean | Disable or enable Nagle`s algorithm. |
| TCPQuickAckDevBoolean | Set this property to true to enable TCP quick acknowledgements |
| NumberOfRetryDevShort | Number Of Retry for all command in case failed. |
| SleepBetweenRetryDevShort | Sleep Between Retry in Miliseconds |
| TCPKeepAliveDevBoolean | Allow to enable/disable the TCP Keep Alive socket option. Defaults to False. |
| PortDevShort | The port of the host modbus connection for the TCP protocol. Defaults to 502 |
Updated:
The device class has been updated.
You can see previous version here .
29 May 2021, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
29 Jun 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Mar 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.