Daresbury - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released, Release: latest
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Security/Daresbury
Contact:



Class Description


Handle PSS crate hardware

Families: Security

Key words:

Platform: Unix Like

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: ESRF

Product:

REL1_0

Bus: Not Applicable

Class interface


Attributes:

Name Description
InterlocksSpectrum: DevShort —

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
DevReadInput: DevVoid
Output: DevString
Serial line response
Returns the response of the PSS hardware.
GetAllDescriptionInput: DevVoid
Output: DevVarStringArray
List of interlock description
—
GetHistoryInfoInput: DevVoid
Output: DevVarLongStringArray
Return a list of interlock logs [date,reason]
Returns a list of known logs.
GetInterlockDescriptionInput: DevVarLongArray
List of Interlock addresses : [Word address,Bit address]*
Output: DevVarStringArray
Interlock descrition string array
—
GetInterlockStateInput: DevVarLongArray
List of Interlock addresses : [Word address,Bit address]*
Output: DevVarCharArray
List of interlock state
—
ReadInterlockHistoryInput: DevLong
Log time , see GetHistoryInfo
Output: DevVarShortArray
Array of interlock
Returns the states of the interlock set of the specified log
ResetInput: DevVoid
Output: DevVoid
Reset the interlock system.
SetInterlockDescriptionInput: DevVarStringArray
argin[0]=Word address argin[1]=Bit address argin[2]=Interlock description
Output: DevVoid
Sets the descripton of the specified interlock.
EnableSMSInput: DevVarLongArray
argin[0]=Word address argin[1]=Bit address
Output: DevVoid
Enable SMS alarm for the specified interlock.
DisableSMSInput: DevVarLongArray
argin[0]=Word address argin[1]=Bit address
Output: DevVoid
Disable SMS alarm for the specified interlock.
GetSMSInput: DevVarLongArray
argin[0]=Word address argin[1]=Bit address
Output: DevBoolean
true if the SMS alarm is enabled for this interlock, false otherwise.
—

Pipes:

Properties:

Name Description
Serial_lineDevString Name of the serial line device
Init_pscomDevShort Flag to force reinitialisation (This is needed on certain old daresbury board) Default is 0 => no initialisation
SMSDeviceDevString Name of the SMS device
SMSPhoneNumberDevString —
MailDestArray of DevString List of mail adress


Please log in to comment.

Generated

PDF generated from POGO



README

b'//-============================================================\n//\n// This class has been generated by POGO\n// (Program Obviously used to Generate tango Object)\n//\n// (c) - Software Engineering Group - ESRF\n//=============================================================\n\n\nFiles generated:\n===============\nDaresbury.cpp: Source code for the Daresbury class and its commands.\n This class is derived from DeviceImpl_2 class.\n It represents the CORBA servant obbject which\n will be accessed from the network.\n All commands which can be executed on the\n Daresbury are implemented in this file.\n\nDaresbury.h: Include for the Daresbury class.\n Server class prototypes and descriptions.\n\nDaresburyClass.cpp: A singleton class derived fromDaresbury.\n It implements the command list and all properties\n and methods required by the Daresbury once per process\n\nDaresburyClass.h:\tInclude for the DaresburyClass root class.\n This class is represents the singleton class for\n the Daresbury device class.\n It contains all properties and methods which the \n Daresbury requires only once e.g. the commands.\n\nmain.cpp:\t\tC++ source for a TANGO device server main.\n The main rule is to initialise (and create) the Tango\n system and to create the DServerClass singleton.\n The main should be the same for every Tango device server.\n\nClassFactory.cpp:\tC++ source for the class_factory method of the DServer\n device class. This method is responsible to create\n all class singletin for a device server. It is called\n at device server startup\n'

29 Jan 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



6 Oct 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



3 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:3 Jan 2017, 2:02 p.m.