Contact:
Class Description
Families: BeamDiagnostics
Key words:
Platform: All Platforms
Language: Python
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| max_xScalar: DevDouble | x coordinate of intensity maxumum within ROI |
| max_yScalar: DevDouble | y coordinate of intensity maxumum within ROI |
| max_intensityScalar: DevDouble | maxumum intensity value in ROI |
| com_xScalar: DevDouble | x coordinate of ROI's center of mass |
| com_yScalar: DevDouble | y coordinate of ROI's center of mass |
| fwhm_xScalar: DevDouble | horizontal size of peak wihtin ROI |
| fwhm_yScalar: DevDouble | vertical size of peak wihtin ROI |
| roi_sumScalar: DevDouble | sum of intensity over ROI |
| scan_parameterScalar: DevString | which parameter will be use as a "source" for Sardana. Can be "max_i", "max_x", "max_y", "com_x", "com_y", "fwhm_x", "fwhm_y", "sum" |
| valueScalar: DevDouble | value to be passed to Sardana |
| roi_xScalar: DevLong | x coordinate of left top ROI corner |
| roi_yScalar: DevDouble | y coordinate of left top ROI corner |
| roi_wScalar: DevDouble | ROI width |
| roi_hScalar: DevDouble | ROI height |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| StartInput: DevVoid Output: DevVoid |
does analysis of last frame |
| StopInput: DevVoid Output: DevVoid |
— |
Pipes:
Properties:
| Name | Description |
|---|---|
| CameraDeviceDevString | Adress of related camera tango server |
7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You can see previous version here .
7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You are looking at this version now.
7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You can see previous version here .
7 Dec 2020, Yury Matveev
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You can see previous version here .
7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You are looking at this version now.
7 Dec 2020, Yury Matveev
Updated:
The device class has been updated.
You can see previous version here .
7 Dec 2020, Yury Matveev
Created:
The device class has been added to catalogue.
Added by:ymatveev
on:7 Dec 2020, 5:01 p.m.