This is historical information of device classes implemented in SerialDevice device server.
Use this link to find the valid information.
Development status:
New development
Information status: New
Contact:
Class Description
Device server to communicate with RS232 devices; this eas written at DESY with DESY beamlines in mind, where we quite have have the situation that for testing / evaluation purposes devices are connected directly to a computer, but will lateron be driven via a terminal server.
This server supports both way, you can switch by setting properties.
Families: Communication
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State Device state |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Device status |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| WriteInput: DevString Output: DevVoid |
Write string given in argin to device |
| ReadInput: DevVoid Output: DevString |
Read string from device |
| WriteReadInput: DevString Output: DevString |
Write string to device and return reply |
Pipes:
Properties:
| Name | Description |
|---|---|
| HostNameDevString | Hostname / IP address of terminal server (if connected via such). |
| PortNumberDevLong | TCP port number on terminal server (if connected via such) |
| DeviceFileDevString | Name of serial device file name (if connected directly), e.g. /dev/ttyS0 |
| BaudRateDevLong | baud rate (if connecting directly) |
| CharSizeDevLong | Character size of serial commuication |
| StopBitsDevLong | Stop bits of serial commuication |
| ParityDevLong | Parity of serial commuication 0: off 1: odd 2: even |
| FlowControlDevLong | Flow controll of serial commuication 0: off 1: odd 2: even |
| TimeOutDevLong | Timeout in ms when reading from device |
| EndOfLineDevString | End of line string in used in communication |
| ConnectTypeDevString | `net` for tcp/ip connection or `serial` for rs232 connection |
Updated:
The device class has been updated.
You can see previous version here .
24 Apr 2021, DS Admin
Updated:
A device class has been added.
You can see previous version here .
24 Apr 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
24 Oct 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .
17 Oct 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
10 Oct 2020, DS Admin
Created:
The device class has been added to catalogue.