SpectroHR460 - - TANGO Controls

This is historical information of device classes implemented in SpectroHR460 device server.

Use this link to find the valid information.

Development status: Released, Release: release_1_0_0
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/MeasureInstruments/SpectroHR460
Contact:



Class Description


This device manages a JobinYvon Horiba HR460 spectrometer, using the GPIB protocol (GPIB Device).

Families: BeamlineComponents

Key words:

Platform: All Platforms

Language: Cpp

License: GPL

Contact:

Hardware


Manufacturer: none

Bus: GPIB

Class interface


Attributes:

Name Description
gratingPositionScalar: DevLong Absolute position of the grating motor, in motor steps.
centralWavelengthScalar: DevDouble Current central wavelength, in nm.
wavelengthOffsetScalar: DevDouble Wavelength offset, in nm.
limitSwitchScalar: DevBoolean Flag for grating motor limit reached.
selectedGratingScalar: DevString Selected grating density, in grooves/mm.
entranceMirrorPositionScalar: DevString Entrance mirror position.
exitMirrorPositionScalar: DevString Exit mirror position.

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
InitMotorsInput: DevVoid
Output: DevVoid
Launch motors initialization.
ResetInput: DevVoid
Output: DevVoid
Reset hardware.
AbortInput: DevVoid
Output: DevVoid
Stop motors.
SelectGratingInput: DevString
grating label
Output: DevVoid
Select new grating.
DefineGratingPositionInput: DevLong
motor position in steps
Output: DevVoid
Define grating position.
DefineSlitPositionInput: DevVarDoubleStringArray
slit name, slit opening in microns
Output: DevVoid
Define slit position.
MoveEntranceMirrorAXIALInput: DevVoid
Output: DevVoid
Move entrance mirror to AXIAL position.
MoveEntranceMirrorLATERALInput: DevVoid
Output: DevVoid
Move entrance mirror to LATERAL position.
MoveExitMirrorAXIALInput: DevVoid
Output: DevVoid
Move exit mirror to AXIAL position.
MoveExitMirrorLATERALInput: DevVoid
Output: DevVoid
Move exit mirror to LATERAL position.

Pipes:

Properties:

Name Description
GpibDeviceUrlDevString Name of the Tango device to access the power supply controller.
ConnectionRetriesDevUShort Number of retries for spectrometer connection.
PollingPeriodDevUShort Polling period of the spectrometer, in ms.
InitMotorsTmoDevUShort Timeout for InitMotors command, in s.
SlitDefinitionArray of DevString Slit definition, with format: {index}:{name}:{description}
GratingDefinitionArray of DevString Grating definition, with format: {index}:{name}
GratingMotorBacklashDevUShort Backlash value for grating motor, in motor steps.

19 Mar 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



22 Aug 2020, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



11 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



4 Jul 2020, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



27 Jun 2020, DS Admin
Created:
The device class has been added to catalogue.
Added by:dadmin on:22 Aug 2020, 3:44 a.m.