Development status:
Released,
Release: Release_1_5
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/SoftwareSystem/Clipboard
Contact:
Class Description
Class for transferring data between different clients.
Families: Miscellaneous
Key words:
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: none
Bus: Not Applicable
Class interface
Attributes:
| Name | Description |
|---|---|
| Line1Scalar: DevString | — |
| Line2Scalar: DevString | — |
| Line3Scalar: DevString | — |
| Line4Scalar: DevString | — |
| Line5Scalar: DevString | — |
| Line6Scalar: DevString | — |
| Line7Scalar: DevString | — |
| Line8Scalar: DevString | — |
| Line9Scalar: DevString | — |
| Line10Scalar: DevString | — |
| TimeStamp1Scalar: DevDouble | — |
| TimeStamp2Scalar: DevDouble | — |
| TimeStamp3Scalar: DevDouble | — |
| TimeStamp4Scalar: DevDouble | — |
| TimeStamp5Scalar: DevDouble | — |
| TimeStamp6Scalar: DevDouble | — |
| TimeStamp7Scalar: DevDouble | — |
| TimeStamp8Scalar: DevDouble | — |
| TimeStamp9Scalar: DevDouble | — |
| TimeStamp10Scalar: DevDouble | — |
| UpdateId1Scalar: DevLong | — |
| UpdateId2Scalar: DevLong | — |
| UpdateId3Scalar: DevLong | — |
| UpdateId4Scalar: DevLong | — |
| UpdateId5Scalar: DevLong | — |
| UpdateId6Scalar: DevLong | — |
| UpdateId7Scalar: DevLong | — |
| UpdateId8Scalar: DevLong | — |
| UpdateId9Scalar: DevLong | — |
| UpdateId10Scalar: DevLong | — |
| Line11Scalar: DevString | — |
| Line12Scalar: DevString | — |
| Line13Scalar: DevString | — |
| Line14Scalar: DevString | — |
| Line15Scalar: DevString | — |
| Line16Scalar: DevString | — |
| Line17Scalar: DevString | — |
| Line18Scalar: DevString | — |
| Line19Scalar: DevString | — |
| Line20Scalar: DevString | — |
| TimeStamp11Scalar: DevDouble | — |
| TimeStamp12Scalar: DevDouble | — |
| TimeStamp13Scalar: DevDouble | — |
| TimeStamp14Scalar: DevDouble | — |
| TimeStamp15Scalar: DevDouble | — |
| TimeStamp16Scalar: DevDouble | — |
| TimeStamp17Scalar: DevDouble | — |
| TimeStamp18Scalar: DevDouble | — |
| TimeStamp19Scalar: DevDouble | — |
| TimeStamp20Scalar: DevDouble | — |
| UpdateId11Scalar: DevLong | — |
| UpdateId12Scalar: DevLong | — |
| UpdateId13Scalar: DevLong | — |
| UpdateId14Scalar: DevLong | — |
| UpdateId15Scalar: DevLong | — |
| UpdateId16Scalar: DevLong | — |
| UpdateId17Scalar: DevLong | — |
| UpdateId18Scalar: DevLong | — |
| UpdateId19Scalar: DevLong | — |
| UpdateId20Scalar: DevLong | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| SetLine1Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine2Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine3Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine4Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine5Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine6Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine7Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine8Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine9Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine10Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine11Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine12Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine13Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine14Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine15Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine16Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine17Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine18Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine19Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
| SetLine20Input: DevString Output: DevLong |
Input new Line value, output UpdateId. |
Pipes:
Properties:
Please log in to comment.