XMCD - - TANGO Controls
.

Average: 0
Rating Count: 0

Development status: Released, Release: Release_2_5
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/OtherInstruments/XMCD
Contact:



Class Description


Computes a current for normalization using the PiLC.

Families: Miscellaneous

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: DESY

Product:

PiLC

Bus: Not Applicable

Class interface


Attributes:

Name Description
IntensityScalar: DevDouble —
IPlusScalar: DevDouble ItPlus/I0Plus
IMinusScalar: DevDouble ItMinus/I0Minus
ItPlusScalar: DevLong —
I0PlusScalar: DevLong —
ItMinusScalar: DevLong —
I0MinusScalar: DevLong —
GateStatusScalar: DevLong —
MirrorDelay1Scalar: DevFloat Reads last written value. The write value is rounded to multiples of 5 ns.
MirrorDelay2Scalar: DevFloat Reads last written value. The write value is rounded to multiples of 5 ns.
ClockCounterScalar: DevDouble —
I0Plus1Scalar: DevLong —
I0Plus2Scalar: DevLong —
I0Minus1Scalar: DevLong —
I0Minus2Scalar: DevLong —
TGAFrequencyScalar: DevDouble Frequency of the PGA. Used to convert PiLC counts to time.
ClockTimeScalar: DevDouble —
IpImDiffScalar: DevDouble Iplus - Iminus
IpImXasScalar: DevDouble - Iplus - Iminus
ItPlus2Scalar: DevLong —
ItMinus2Scalar: DevLong —
ModeScalar: DevLong Mode for Iplus and Iminus calculation: 0 -> absortion, 1 -> fluorescence/diffraction
ModeInfoScalar: DevString Shows selected mode in Mode attribute.
IDirectionScalar: DevLong 0 -> I-, 1 -> I+
ObservationsScalar: DevString Attribute for writing information
PiLCNameScalar: DevString Name of the PiLC Tango device connected to

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.

Pipes:

Properties:

Name Description
PiLCDeviceDevString Name of the PiLCDevice connecting to the hw.
InitPiLCAtStartDevLong If set to 1, the PiLC is initilized when the server is started.


Please log in to comment.

14 May 2022, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



13 Nov 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



26 Jun 2021, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



25 Aug 2018, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .



2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.
Added by:pgoryl2 on:2 Jan 2017, 2:57 p.m.