This is historical information of device classes implemented in Socket device server.
Use this link to find the valid information.
Development status:
Released,
Release: Release_1_6
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Communication/DESY/Socket
Contact:
Class Description
This class implements basic socket IPC.
Families: Communication
Key words:
Platform: Unix Like
Language: Cpp
License: GPL
Contact:
Hardware
Manufacturer: none
Bus: Data Socket
Class interface
Attributes:
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State State Code |
This command gets the device state (stored in its <i>device_state</i> data member) and returns it to the caller. |
| StatusInput: DevVoid Output: ConstDevString Status description |
This command gets the device status (stored in its <i>device_status</i> data member) and returns it to the caller. |
| WriteInput: DevString Output: DevVoid |
Command used to send a string to the socket. |
| ReadInput: DevVoid Output: DevString |
Command used to read a string from the socket. |
| ReconnectInput: DevVoid Output: DevVoid |
Attempts to re-establish the socket connection. |
| WriteAndReadInput: DevString Command string. Output: DevString Answer string. |
Write to the socket and waits for the answer. The end of the answer is triggered by the new line character! |
| ReadlnInput: DevVoid Output: DevString argout |
Reads from a socket until a "\n" has been received. |
| ReadUntilInput: DevString This is the terminator Output: DevString This is the read string. |
This command read data from the socket until the terminator has been reached. |
| WriteReadUntilInput: DevVarStringArray [0] = Command string to be send, [1] = end of message character Output: DevString Answer string. |
Write to the socket and waits for the answer. The answer is triggered by select() which indicates that the the anser has arrived. |
| WriteTwoBytesInput: DevLong Pair ID Output: DevVoid |
Write two hardcoded bytes: 0 -> 0x1, 0x30 1 -> 0x1, 0x31 2 -> 0x1, 0x32 |
Pipes:
Properties:
| Name | Description |
|---|---|
| HostnameDevString | This is the hostname of the host to connect to. |
| PortDevLong | This is the port number to connect to. |
| ReadtimeoutDevShort | Read timeout in milliseconds. |
| AutoReconnectDevBoolean | If true, the server try to re-create and re-connect to the socket after a failure. NOTE : The default values is false. |
| SimulationModeDevLong | 0 if not simulation |
README
b'This software was developed by the ESRF. It is included in the\n svn repository for having it available with the DESY developed\nServers.\n'
Updated:
The device class has been updated.
You are looking at this version now.
23 Feb 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
19 Jan 2017, Piotr Goryl
Updated:
The device server has been updated.
You can see previous version here .
2 Jan 2017, Piotr Goryl
Created:
The device server has been added to catalogue.