KromoTX1easyXAFS - - TANGO Controls

This is historical information of device classes implemented in KromoTX1easyXAFS device server.

Use this link to find the valid information.

Development status: Released, Release: Release_1_0
Information status: Updated
Repository: http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/Acquisition/2D/KromoTX1easyXAFS
Contact:



Class Description


Class for controlling the Kromo-TX1 color tender X-ray camera from easyXAFS

Families: Acquisition

Key words:

Platform: Unix Like

Language: Python

License: GPL

Contact:

Hardware


Manufacturer: easyXAFS

Product:

Kromo-TX1 Color Tender X-ray camera

Bus: USB

Class interface


Attributes:

Name Description
ExpositionTimeScalar: DevDouble
GainScalar: DevLong Read gain from the camera. The set value is given in the property Gain of the tango device.
FramesPerSecondScalar: DevDouble Read the fps from the camera. The value is set from the property of the tango device. If HighSpeedMode == 0 -> max value is 80 If HighSpeedMode == 1 -> max values is 170
HighSpeedModeScalar: DevLong 0-> off, 1-> on
FileDirScalar: DevString Save directory
FilePrefixScalar: DevString Prefix of the file were the data and parameters are save. Data is saved in [FilePrefix][FileIndex]_array.npy. Parameters in [FilePrefix]_parameters. If the file [FilePrefix][FileIndex]_parameters exists, the data are loaded and not new data are taken.
TemperatureScalar: DevDouble
WindowMinScalar: DevLong Show current window (set in the property).
WindowMaxScalar: DevLong Show current window (set in the property).
FileIndexScalar: DevLong Index to append to the file name. It will be increased by one after use. Avoid loading of files if not explicitly wanted.
TotalAverageCountsScalar: DevDouble Total counts in RoI (depends on PhotonValue)
PhotonValueScalar: DevDouble Average pixel value counted in the detector
RoI1MinScalar: DevLong RoI for computing counts
RoI1MaxScalar: DevLong RoI for computing counts
RoI2MinScalar: DevLong RoI for computing counts
RoI2MaxScalar: DevLong RoI for computing counts
RoI1CountsScalar: DevDouble Counts in RoI1
RoI2CountsScalar: DevDouble Counts in RoI2
PixelSizeScalar: DevDouble Resize the pixel. If -1 is not used.
DataSpectrum: DevDouble
FrameImage: DevDouble Depends on PhotonValue
ResizedFrameImage: DevDouble Resized frame using PixelSize attribute.

Commands:

Name Description
StateInput: DevVoid
Output: State
Device state
This command gets the device state (stored in its device_state data member) and returns it to the caller.
StatusInput: DevVoid
Output: ConstDevString
Device status
This command gets the device status (stored in its device_status data member) and returns it to the caller.
StartAcquisitionInput: DevVoid
Output: DevVoid
Start acquisition
StopAcquisitionInput: DevVoid
Output: DevVoid

Pipes:

Properties:

Name Description
kromo_pidsArray of DevLong Process ids from last server running. Filled by the tango device.
WindowMinDevLong Window min (for photon processing)
WindowMaxDevLong Window max (for photon processing)
ThresholdDevLong Threshold
DeclusterDevLong 0-> false, 1->true
GainDevLong Gain of the camera
FramesPerSecondDevDouble Frames per second If HighSpeedMode == 0 -> max value is 80 If HighSpeedMode == 1 -> max values is 170
AnalysisModeDevLong If 1, it works without detector, only loading files.

README

b'It can not be started with Astor if the remaining threads are not killed\nper hand. The starting script and the Tango Server kill them at init.'

6 Apr 2019, DS Admin
Updated:
The device class has been updated.
You can see previous version here .



28 Apr 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.



21 Oct 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .



16 Sep 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2 on:28 Apr 2018, 3:07 a.m.