This is historical information of device classes implemented in Ni6602 device server.
Use this link to find the valid information.
Development status:
Released,
Release: initial
Information status: Updated
Repository:
http://svn.code.sf.net/p/tango-ds/code/DeviceClasses/CounterTimer/NI/Ni6602
Contact:
Class Description
Device Server for National Instruments 6602 high-speed counter/timer card.
Families: CounterTimer
Key words: NI
Language: Cpp
Contact:
Class interface
Attributes:
| Name | Description |
|---|---|
| TimeScalar: DevDouble | — |
| EstimatedIntegrationTimeScalar: DevDouble | — |
| TimeBaseSpectrum: DevDouble | — |
| TimeSourceSpectrum: DevString | — |
| CounterSpectrum: DevDouble | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ResetInput: DevVoid Output: DevVoid |
Abort counting and reset card |
| StartInput: DevVoid Output: DevVoid |
Starts measurement tasks. Counter channels have to be configured first! |
| ConfigCounterInput: DevVarLongArray Output: DevVoid |
\n used as master channel\n 9 - edge count on specified channel using a master channel |
| AbortInput: DevVoid Output: DevVoid |
Aborts all measurement tasks. |
| AbortTaskInput: DevLong Output: DevVoid |
Aborts the task running on the specified counter channel. |
Pipes:
Properties:
| Name | Description |
|---|---|
| CtrDeviceDevString | NI system device name |
| UseDebugDevShort | Specifies if extra debugging information should be produced. |
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.