Class Description
Families: Communication
Key words: Instrumentation
Platform: All Platforms
Language: Python
Contact:
Hardware
Manufacturer: none
Bus: Visa
Class interface
Attributes:
| Name | Description |
|---|---|
| clickScalar: DevBoolean | — |
| beeperScalar: DevBoolean | — |
| lockScalar: DevBoolean | — |
| errorListSpectrum: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| ResetInput: DevVoid Output: DevVoid |
None. |
| StartInput: DevVoid Output: DevVoid |
None. |
| StopInput: DevVoid Output: DevVoid |
None. |
| LockInput: DevVoid Output: DevVoid |
None. |
| UnlockInput: DevVoid Output: DevVoid |
None. |
| IDNInput: DevVoid Output: DevString |
None. |
| CMDInput: DevString Output: DevString |
None. |
| OpenChInput: DevShort Output: DevVoid |
None. |
| CloseChInput: DevShort Output: DevVoid |
None. |
| ChannelStateInput: DevShort Output: DevBoolean |
None. |
| InitVisaInput: DevVoid Output: DevVoid |
None. |
| ResetVisaInput: DevVoid Output: DevVoid |
None. |
Pipes:
Properties:
| Name | Description |
|---|---|
| NumChannelsDevShort | This information is used to generate dynamically the number of spaces will be in much of the spectrum values. |
| PyVisaDSDevString | The tango name of the PyVisaDS who is connected to the oscilloscope. |
| logger_maxlenDevLong | A positive number to tune the number of characters of data to throw on the log file. |
| LockInstrumentDevBoolean | Lock the front panel of the instrument on the device start up. |
22 Feb 2018, DS Admin
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.
Added by:pgoryl2
on:22 Feb 2018, 2:30 p.m.