This is historical information of device classes implemented in i-tech-photon device server.
Use this link to find the valid information.
Development status:
Released
Information status: Updated
Contact:
Class Description
IT Libera BPM Device Server
Families: BeamDiagnostics
Key words: BeamDiag
Platform: Unix Like
Language: Cpp
Contact:
Hardware
Manufacturer: I-Tech
Product:
Libera Photon
Bus: Ethernet
Class interface
Attributes:
| Name | Description |
|---|---|
| LiberaModelScalar: DevUShort | — |
| DDEnabledScalar: DevBoolean | — |
| DDBufferSizeScalar: DevLong | — |
| DDDecimationFactorScalar: DevUShort | — |
| DDTriggerOffsetScalar: DevLong | — |
| DDBufferFreezingEnabledScalar: DevBoolean | — |
| DDBufferFrozenScalar: DevBoolean | — |
| DDTriggerCounterScalar: DevLong | — |
| ExternalTriggerEnabledScalar: DevBoolean | — |
| ExternalTriggerDelayScalar: DevLong | — |
| SAEnabledScalar: DevBoolean | — |
| XPosSAScalar: DevDouble | — |
| ZPosSAScalar: DevDouble | — |
| VaSAScalar: DevDouble | — |
| VbSAScalar: DevDouble | — |
| VcSAScalar: DevDouble | — |
| VdSAScalar: DevDouble | — |
| SumSAScalar: DevDouble | — |
| IaSAScalar: DevDouble | — |
| IbSAScalar: DevDouble | — |
| IcSAScalar: DevDouble | — |
| IdSAScalar: DevDouble | — |
| ISumSAScalar: DevDouble | — |
| SAStatNumSamplesScalar: DevLong | — |
| XMeanPosSAScalar: DevDouble | — |
| ZMeanPosSAScalar: DevDouble | — |
| XRMSPosSAScalar: DevDouble | — |
| ZRMSPosSAScalar: DevDouble | — |
| XPeakPosSAScalar: DevDouble | — |
| ZPeakPosSAScalar: DevDouble | — |
| SumMeanSAScalar: DevDouble | — |
| ADCEnabledScalar: DevBoolean | — |
| ADCBufferSizeScalar: DevLong | — |
| PMDecimationFactorScalar: DevUShort | — |
| PMOffsetScalar: DevLong | — |
| PMNotifiedScalar: DevBoolean | — |
| PMNotificationCounterScalar: DevShort | — |
| InterlockXNotifiedScalar: DevBoolean | — |
| InterlockZNotifiedScalar: DevBoolean | — |
| InterlockBiasCurrentLimitNotifiedScalar: DevBoolean | — |
| InterlockBiasOverCurrentNotifiedScalar: DevBoolean | — |
| InterlockADCOverflowNotifiedScalar: DevBoolean | — |
| XLowScalar: DevDouble | — |
| XHighScalar: DevDouble | — |
| ZLowScalar: DevDouble | — |
| ZHighScalar: DevDouble | — |
| OffsetTuneScalar: DevLong | — |
| ARCEnabledScalar: DevBoolean | — |
| RangeScalar: DevUShort | — |
| BiasVoltageSourceModeScalar: DevShort | — |
| BiasVoltage0Scalar: DevLong | — |
| BiasVoltage1Scalar: DevLong | — |
| BiasScalar: DevShort | — |
| MachineTimeScalar: DevDouble | — |
| TimePhaseScalar: DevLong | — |
| SystemTimeScalar: DevDouble | — |
| SCPLLStatusScalar: DevBoolean | — |
| MCPLLStatusScalar: DevBoolean | — |
| DigitalBoardTemperatureScalar: DevShort | — |
| InnerShieldTemperatureScalar: DevLong | — |
| OuterShieldTemperatureScalar: DevLong | — |
| Fan1SpeedScalar: DevShort | — |
| Fan2SpeedScalar: DevShort | — |
| UpTimeScalar: DevLong | — |
| CpuUsageScalar: DevLong | — |
| FreeMemoryScalar: DevLong | — |
| RamFsUsageScalar: DevLong | — |
| UseLiberaPosDataScalar: DevBoolean | — |
| PositionAlgorithmScalar: DevUShort | — |
| InsertionDeviceGapScalar: DevUShort | — |
| AutoCalibrationModeScalar: DevUShort | — |
| XPosDDSpectrum: DevDouble | — |
| ZPosDDSpectrum: DevDouble | — |
| SumDDSpectrum: DevDouble | — |
| VaDDSpectrum: DevDouble | — |
| VbDDSpectrum: DevDouble | — |
| VcDDSpectrum: DevDouble | — |
| VdDDSpectrum: DevDouble | — |
| IaDDSpectrum: DevDouble | — |
| IbDDSpectrum: DevDouble | — |
| IcDDSpectrum: DevDouble | — |
| IdDDSpectrum: DevDouble | — |
| ISumDDSpectrum: DevDouble | — |
| XPosSAHistorySpectrum: DevDouble | — |
| ZPosSAHistorySpectrum: DevDouble | — |
| SumSAHistorySpectrum: DevDouble | — |
| XPosPMSpectrum: DevDouble | — |
| ZPosPMSpectrum: DevDouble | — |
| SumPMSpectrum: DevDouble | — |
| VaPMSpectrum: DevDouble | — |
| VbPMSpectrum: DevDouble | — |
| VcPMSpectrum: DevDouble | — |
| VdPMSpectrum: DevDouble | — |
| ADCChannelASpectrum: DevLong | — |
| ADCChannelBSpectrum: DevLong | — |
| ADCChannelCSpectrum: DevLong | — |
| ADCChannelDSpectrum: DevLong | — |
| UserDataSpectrum: DevShort | — |
| InterlockConfigurationSpectrum: DevDouble | — |
| logsSpectrum: DevString | — |
Commands:
| Name | Description |
|---|---|
| StateInput: DevVoid Output: State |
This command gets the device state (stored in its device_state data member) and returns it to the caller. |
| StatusInput: DevVoid Output: DevString |
This command gets the device status (stored in its device_status data member) and returns it to the caller. |
| DisableADCInput: DevVoid Output: DevVoid |
Disables the so called ADC data source |
| DisableDDInput: DevVoid Output: DevVoid |
Disables the so called "data on demand" (i.e. first turns) data source |
| DisableDDBufferFreezingInput: DevVoid Output: DevVoid |
Disables the DD buffer freezing mechanism |
| DisableSAInput: DevVoid Output: DevVoid |
Disables the so called "slow acquisition" data source |
| EnableADCInput: DevVoid Output: DevVoid |
Enables the so called ADC data source |
| EnableDDInput: DevVoid Output: DevVoid |
Enables the so called "data on demand" (i.e. first turns) data source |
| EnableDDBufferFreezingInput: DevVoid Output: DevVoid |
Enables the DD buffer freezing mechanism |
| EnableSAInput: DevVoid Output: DevVoid |
Enables the so called "slow acquisition" data source |
| GetParametersInput: DevVoid Output: DevVarDoubleStringArray |
Retruns the current gains and offsets (i.e. the parameters used for position computation) |
| ReadFADataInput: DevVarLongArray Output: DevVarLongArray |
Statring from[offest] in FA data block, reads [size of elems] * [num of elems] bytes. |
| ReloadSystemPropertiesInput: DevVoid Output: DevVoid |
None. |
| ResetInterlockNotificationInput: DevVoid Output: DevVoid |
Resets the interlock notification flags to false |
| ResetPMNotificationInput: DevVoid Output: DevVoid |
None. |
| SetInterlockConfigurationInput: DevVoid Output: DevVoid |
Change interlock configuration using the InterlockConfiguration class (or device) property. Only modify the interlock configuration, the remaining env. parameters remain unchanged. |
| SetTimeOnNextTriggerInput: DevVoid Output: DevVoid |
Applies both machine et system time values on next trigger |
| UnfreezeDDBufferInput: DevVoid Output: DevVoid |
Unfreezes the DD buffer |
| WriteFADataInput: DevVarLongArray Output: DevVoid |
Starting from [offset] in Fa data block, writes [size of elems * num of elems]. The actual data to be written starts at index [4] in the input array. |
Pipes:
Properties:
| Name | Description |
|---|---|
| InterlockConfigurationDouble[]Type | The user defined interlock configuration. This is the configuration that should be applied on the Libera in case the device `finds` the Libera in its default startup configuration when it is itself starting up or executing its Init TANGO command. This configuration can also be applied using the dedicated ``SetInterlockConfiguration`` expert command. Parameters mapping: [0] Interlock : mode - [0]: disabled, [1]: enabled, [3]: enabled with gain dependency [1] Interlock : threshold : X low in mm [2] Interlock : threshold : X high in mm [3] Interlock : threshold : Z low in mm (i.e. Y low in the Libera terminology) [4] Interlock : threshold : Z high in mm (i.e. Y high in the Libera terminology) [5] Interlock : overflow limit (ADC threshold) [6] Interlock : overflow duration (num of overloaded ADC samples before raising intlck) [7] Interlock : gain limit in dBm (intlck not active under this limit) - valid range is [-60, 0] |
| EnableDDOptionalDataDevBoolean | Enables/Disables DD optional data (IxDD and QxDD) |
| EnableSAOptionalDataDevBoolean | Enables/disables SA optional Data (currently not used) |
| EnableSAHistoryOptionalDataDevBoolean | Enables/disables SA History optional data (sum history) |
| EnableADCOptionalDataDevBoolean | Enables/disables ADC optional data (currently not used) |
| InstituteDevShort | 0: TANGO_INSTITUTE (GENERIC) 1: ALBA 2: ESRF 3: ELETTRA 4: SOLEIL |
| ADCTaskActivityPeriodDevLong | Specifies the data reading period in ms. Must be in the range [500, 25000] ms. Defaults to 1000. |
| BladesKiInt[]Type | The blades `Ki` coefficients (array of signed 32bits integer values) |
| BladesLeakageInt[]Type | The blades `leakage` values (array of signed 32bits integer values) |
| BladesIOffsetInt[]Type | The blades `i-offset` values (array of signed 32bits integer values) |
| DDDecimationFactorDevShort | The DD decimation factor. Allowed values : 1 (no decimation) or 64 (for the so called booster normal mode) |
| DDTaskActivityPeriodDevLong | Specify the watch-dog (1) or data reading period (2) in ms. Must be in the rangec [500, 25000] ms. Defaults to 1000. (1) : external trigger enabled - (2) : external trigger disabled. |
| DefaultADCBufferSizeDevLong | Default [or initial] value for attribute ADCBufferSize [in samples]. Defaults to 1024. |
| DefaultDDBufferSizeDevLong | Default [or initial] value for attribute DDBufferSize [in samples]. Defaults to 1024. |
| DefaultSAStatNumSamplesDevLong | Default number of SA history samples to use form RMS pos. computation. Defaults to 10 (last second in the SA history). |
| DefaultTimePhaseValueDevLong | Default value for the machine time phase. Its valid range is [0, RfSfRatio - 1] where RfSfRatio is a machine dependent system property. |
| EnableADCDevBoolean | Specifies whether or not the ADC data source should be enabled at startup. Defaults to false. |
| EnableADCOptionalDataDevBoolean | Enables/disables ADC optional data (currently not used) |
| EnableDDDevBoolean | Specifies whether or not the DD data source should be enabled at startup. Defaults to false. |
| EnableDDOptionalDataDevBoolean | Enables/Disables DD optional data (IxDD and QxDD) |
| EnableExternalTriggerDevBoolean | Enables (or not) the external trigger source. Inlfuences the TANGO device behaviour not the Libera itself. Defaults to false. |
| EnableSADevBoolean | Specifies whether or not the SA data source should be enabled at startup. Defaults to false. |
| EnableSAHistoryOptionalDataDevBoolean | Enables/disables SA History optional data (sum history) |
| EnableSAOptionalDataDevBoolean | Enables/disables SA optional Data (currently not used) |
| FADataCacheRefreshPeriodDevLong | The cache refresh period in msecs. Defaults to 500 ms (2Hz). |
| InterlockConfigurationType | The user defined interlock configuration. This is the configuration that should be applied on the Libera in case the device `finds` the Libera in its default startup configuration when it is itself starting up or executing its Init TANGO command. This configuration can also be applied using the dedicated `SetInterlockConfiguration` expert command. Parameters mapping: [0] Interlock : mode - [0]: disabled, [1]: enabled, [3]: enabled with gain dependency [1] Interlock : threshold : X low in mm [2] Interlock : threshold : X high in mm [3] Interlock : threshold : Z low in mm (i.e. Y low in the Libera terminology) [4] Interlock : threshold : Z high in mm (i.e. Y high in the Libera terminology) [5] Interlock : overflow limit (ADC threshold) [6] Interlock : overflow duration (num of overloaded ADC samples before raising intlck) [7] Interlock : gain limit in dBm (intlck not active under this limit) - valid range is [-60, 0] |
| InterlockUnderflowDevLong | Interlock Underflow (signed 32bits integer value) |
| KxDevDouble | Kx. Defaults to 1.0 |
| KzDevDouble | Kz. Defaults to 1.0. |
| LiberaIpAddrDevString | The Libera IP address [no default value] |
| LiberaMulticastIpAddrDevString | Asynch. notifications (e.g. trigger events) will be send to this addr [no default value] |
| LiberaPortDevShort | The port on which the generic server handles external requests. Defaults to 23721. |
| LocationDevString | The BPM location [TL1, BOOSTER, TL2 or STORAGE_RING]. No default value. |
| MaxDDBufferSizeWhenDecimationEnabledDevLong | Max. DD buffer size when decimation enabled on DD data source. Defaults to 10000 |
| PassBBAOffsetsToFPGADevBoolean | Controls wether or not the BBA offsets are taken into account when computing the offsets passed to the FPGA process |
| PMDecimationFactorDevShort | The PM decimation factor. Allowed values : 1 (no decimation) or 64 (for the so called booster normal mode) |
| SAHistoryLengthDevLong | SA history buffer length [in samples]. Defaults to 8196. |
| SATaskActivityPeriodDevLong | Specify the watch-dog (1) or data reading period (2) in ms. Must be in the range [100, 25000] ms. Defaults to 100. |
| VtoIConvFactorDevDouble | Conv. factor for DD Vx to Ix computation : Ix = k * Vx / R Defaults to 3.2768/2^31. |
README
b'THIS CSPI 2.2O (WITH LIBERA PHOTON SUPPORT)\n'
Updated:
The device class has been updated.
You are looking at this version now.
20 Apr 2017, Piotr Goryl
Updated:
The device class has been updated.
You can see previous version here .
23 Feb 2017, Piotr Goryl
Created:
The device class has been added to catalogue.